INSTALLATION
3
The Friedrich VRP has been carefully engineered and manufactured to provide many years of dependable, efficient operation
while maintaining a comfortable temperature and humidity level. Many extra features have been built into the unit to ensure
quiet operation, optimal circulation of cool, dry air, and the most economic operation.
Please carefully read and follow the installation insrtructions and safety warnings detailed in this manual. All applicable na-
tional and local mechanical and electrical codes should be followed and take precedence over any Friedrich requirements or
reccomenedations regarding installation applications detailed in this manual.
WARNING
Refrigeration system under high pressure. Do not punc-
ture, heat, expose to flame or incinerate. Only certified
refrigeration technicians should service this equipment.
R410A systems operate at higher pressures than R22
equipment. Appropriate safe service and handling prac-
tices must be used. Only use gauge sets designed for use
with R410A. Do not use R22 gauge sets. Failure to do so
can result in property damage, personal injury, or death.
WARNING
Please read this manual thoroughly prior to equipment
installation or operation. It is the installer’s responsibility
to properly apply and install the equipment. Installation
must be in conformance with the NFPA 70-2008 National
Electric Code or current edition, International Mechanic
code 2009 or current edition and any other applicable local
or national codes.
Your safety and the safety of others are very
important.
We have provided many important safety messages in
this manual and on your appliance. Always read and
obey all safety messages.
This is the safety Alert symbol.
This symbol alerts you to potential
hazards that can kill or hurt you
and others.
All safety messages will follow the
safety alert symbol with the word
“WARNING” or “CAUTION”.
These words mean:
Indicates a hazard which, if not avoided, can result in
severe personal injury or death and damage to product or
other property.
Indicates a hazard which, if not avoided, can result in
personal injury and damage to product or other property.
All safety messages will tell you how to reduce the chance
of injury, and tell you what will happen if the instructions
are not followed.
Indications property damage can occur if instructions
are not followed.
WARNING
CAUTION
NOTICE
WARNING
Electrical shock hazard.
Turn OFF electric power before service or installation.
Unit must be properly grounded.
Unit must have correct fuse or circuit breaker pro-
tection. Unit’s supply circuit must have the correct
wire conductor size. All electrical connections and
wiring must be installed by a qualified electrician and
conform to the National Electrical Code and all local
codes which have jurisdiction. Failure to do so can
result in property
damage, personal injury and/or death.
Содержание VRP12K
Страница 30: ...30 OPERATION FreshAire Control To engage the FreshAire system flip the switch into the ON position ...
Страница 46: ...46 OPERATION Component Identification Indoor Coil 36k ...
Страница 47: ...47 OPERATION Component Identification Indoor Blower BLDC Counter Clockwise Impeller 600 1300 RPM ...
Страница 48: ...48 OPERATION Component Identification Outdoor Coil Monitored by 1 thermistor ...
Страница 49: ...49 OPERATION Component Identification Outdoor Fan BLDC Variable Speed 600 1000 RPM ...
Страница 53: ...53 OPERATION Component Identification 4 Way Reversing Valve 208 230v Reversing valve assembly ...
Страница 177: ...177 UPDATING VRP FIRMWARE Or ...
Страница 184: ...184 UPDATING VRP FIRMWARE Open zip file Copy to SD Card Insert into SD Card Slot ...
Страница 193: ...193 UPDATING VRP FIRMWARE Retrieving VRP Data Remove SD Card from FMC and Locate DF Folder ...
Страница 194: ...194 UPDATING VRP FIRMWARE Retrieving VRP Data Right Click Data txt Send to Compressed zipped folder ...
Страница 196: ...196 WIRINGDIAGRAMS 12 24K BTU 208 230V 7 5 10 0 KW Figure 801 Wiring Diagram ...
Страница 197: ...197 WIRING DIAGRAMS 12 24K BTU 208 230V 2 5 3 4 5 0 KW Figure 802 Wiring Diagram ...
Страница 198: ...198 WIRING DIAGRAMS 12 24K BTU 265V 2 5 3 4 5 0 kW Figure 803 Wiring Diagram ...
Страница 199: ...199 WIRING DIAGRAMS 12 24K BTU 265V 7 5 10 kW Figure 804 Wiring Diagram ...
Страница 200: ...200 WIRING DIAGRAMS 36K BTU 208 230V Figure 805 Wiring Diagram ...
Страница 214: ...214 PARTS CATALOG 36k Control Box Diagram Figure 906 12 12 11 13 10 8 4 3 2 16 5 6 7 1 9 10 9 10 11 11 14 15 ...