COMPONENTS TESTING
Compressor
DC
INVERTER
&
R U
( )
S V
( )
CONTROLLER
T W
(
)
POWER
OVERLOAD
PROT
ECTION
Resistance Test.
The compressor is at fault if the resistance of winding is 0(short circuit)or
∞
open circuit.
Common signs compressor is faulty:
•
Compressor motor lock.
•
Discharge pressure value approaches static pressure value .
•
Compressor motor winding abnormality.
Note:
•
Don’t put a compressor on its side or turn over.
•
Assemble the compressor quickly after removing the plugs. Prolonged exposure will damage the internal components
of the compressor
•
Ensure wiring is correct before operating. Reverse operation will permanently damage the compressor.
• Electric Reactor
Common Problems:
•
Sound abnormality
•
Runs in a sporadic rhythm.