 Rev 3 Service Manual MCC Hot / Cold 2021

Page 13 

Refer to User manual for installation procedure

3.2  Mounting of optional front doors.

 

There are 2 different heights of plastic washers to align the height of the front  doors. 

 

Position the doors with the handles to the outside and with the warning sticker above the handle.

 

Top Hinge

Bottom Hinge

Assy front door MCC 90 SS = 9380104 Complete set to order = 9389832

Содержание Cold MCC

Страница 1: ...onvenience counters MCC configurations and is not intended to be all encompassing The individual specifications may differ Procedures for which you do not have the necessary tools instruments or skill...

Страница 2: ...ion maintenance or repair activities even if not explicitly described in this manual As a result of constant commitment to improvement it may happen that your unit deviates in detail from what is desc...

Страница 3: ...CC Hot Settings Self Serve 62 10 0 Trouble Shooting 65 11 0 Replacement and Adjustments 78 12 0 Technical Specifications MCC Cold Self Serve 92 13 0 Exploded view MCC Hot Self Serve 104 14 0 Exploded...

Страница 4: ...oltage Frequency Power consumption 1 3 Pictograms and symbols In this manual the following pictograms and symbols are used WARNING symbols WARNING WARNING Possible physical injury or serious Risk of F...

Страница 5: ...and carefully follow all guidelines and instructions Never change the order of the steps to be performed The pictograms labels instructions and warning signs attached to the unit are part of the safet...

Страница 6: ...unit in a well ventilated area with sufficient floor space refer to the data sheet for minimum space requirement Do not install the unit in basements in area s with open flames or high surface temper...

Страница 7: ...ort The electrical schematics of the unit are included at the end of this manual In case of malfunctions which are not fixable by you you can contact Fri Jado Make sure you have the following data ava...

Страница 8: ...t always be kept in place For MCC Cold SS Price rail is integrated part of air guidance inside the unit Removing the price rail will result in a bad functioning MCC Self serve models have an additiona...

Страница 9: ...over models between 40 C and 85 C 104 F and 185 F One LED module per level provides lighting of the products The LED lighting and the heating are switched on and off separately In the future Lightning...

Страница 10: ...nstalled operated and serviced in a safe manner the instructions provided by the manufacturer should be adhered to at all times The cabinets can also be supplied with or without under frame to be inst...

Страница 11: ...be done either by hand or automatically For the automatic filling system an additional electrical box is implemented which controls the filling process Hand filling system Automatic filling system Ho...

Страница 12: ...l and contact the transporter as soon as possible but at the latest within fifteen working days after receiving the goods 3 1 Unpacking the unit The MCC is placed inside a crate during transport take...

Страница 13: ...nting of optional front doors There are 2 different heights of plastic washers to align the height of the front doors Position the doors with the handles to the outside and with the warning sticker ab...

Страница 14: ...the door in a tilted position during this action Press the hinge pin at the upper side downwards Turn the door in a vertical position so the upper hinge pin will align with the upper hole Release the...

Страница 15: ...unit s legs Refer to next page MCC cold Please take notice of label with minimum space required Be sure that the personnel have sufficient room to work with the unit Keep a distance of at least 150 mm...

Страница 16: ...al price rails for Hot self serve models can be mounted using the front screws underneath each of the Hot SS shelves Do not loosen this screws entirely Price rails for serve over models can be mounted...

Страница 17: ...of horizontal levels Refer to user manual 4 5 Solid back option On request the unit can be ordered having a solid back in stead of sliding doors 4 6 First use Before starting to use the unit clean the...

Страница 18: ...nth by attaching it to both rear Adjustable legs using its two clamps Insert the pegs of both side plinths into the slots of the rear plinth Secure the side plinths by inserting the pegs into the slot...

Страница 19: ...ication 1 Turn of unit and pull power plug from wall outlet 2 Open back panel of unit refer 11 16 3 Extend drain of unit using the delivered drain pipe Cut pipe on required length depending on measure...

Страница 20: ...Page 20 Rev 3 Service Manual MCC Hot Cold 2021 Circuit diagram evaporator tray...

Страница 21: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 21 Wiring diagram evaporator tray...

Страница 22: ...ure controller Let the unit cool for approx 30 minutes Loading the unit Only load products of which the temperature is maximum 4 C 39 2 F The maximum loading height is 50mm 2 inch below the bottom of...

Страница 23: ...384461 MCC 90 Shelf insert 400x475 mm Middle Shelf 9384470 MCC 90 Shelf insert 400x550 mm Bottom Shelf 9384471 MCC 90 Shelf insert 550x410 mm Top Shelf 9384537 MCC120 Shelf insert 550x475 mm Middle Sh...

Страница 24: ...389813 9389813 Price rail set MCC 150 9389814 9389814 9389814 Evaporation tray 9389820 9389820 9389820 Bumper MCC 90 9380207 9380207 9380207 Bumper MCC 120 9380205 9380205 9380205 Bumper MCC 150 93802...

Страница 25: ...Cold 2021 Page 25 5 0 MCC Drop in Doc nr 9124590 Rev 0 Registration form MCC Drop in Unpack instruction The MCC Drop in will be delivered packed in a crate Start unpacking by removing top cover For i...

Страница 26: ...9124590 Rev 0 Registration form MCC Drop in Unpack instruction Remove short sides first Left and Right by unscrewing them Next remove front and back panel they are also screwed onto the support beams...

Страница 27: ...ve corner pieces EPS foam Unit is placed on a metal sub frame for transport purposes Frame is kept together with metal strip at the front and the back Keep strip in place during placing process Keep w...

Страница 28: ...documents and glass shelfs from unit After placing cabinet in final position remove tie wraps which hold the shelf holders Make sure the shelf holders are placed in the required sleeve for the wanted...

Страница 29: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 29 5 1 MCC 90 Drop in Dimensions Self Serve...

Страница 30: ...00 475 x 1400 Dimensions top shelf mm n a 410 x 800 410 x 1100 410 x 1400 Shelf display area m2 n a 1 18 1 62 2 07 Usable display volume l n a 258 355 452 Drain diameter mm n a 32 Minimum room floor a...

Страница 31: ...ote Airflow inside the cabinet is crucial Air intake and Air outlet are not allowed to interfere A physical barrier must be placed in between the two air flows Air inlet and air outlet surfaces must c...

Страница 32: ...es the back panel of the counter can be removed Provide enough space to place the counter with a stacker Maintain the dimensions and minimum height as indicated in the installation manual also applies...

Страница 33: ...till easily accessible for service after installation by means of a removable hatch Provide enough space to place the counter with a stacker Maintain the dimensions and minimum requirements as indicat...

Страница 34: ...x D x H mm 720 x 870 x 1460 1020 x 870 x 1460 1320 x 870 x 1460 Nr of presentation levels 3 n a Dimensions bottom shelf mm 550 x 500 550 x 800 550 x 1100 n a Dimensions middle shelf mm 475 x 500 475 x...

Страница 35: ...allation instruction 3 Step 1 Position the cabinet above the cut out in the counter top with a forklift and support it using the wooden beams supplied with the unit Step 2 Lift the cabinet from below...

Страница 36: ...4589 Rev 0 Registration form MCC Drop in installation instruction 4 Step 3 Apply sealant or a thin flexible foam seal around the cut out in the countertop Carefully lower the cabinet into the counter...

Страница 37: ...e and screws up to 1 meter from the original position Step 6 Install a partition panel to prevent recirculation of hot condenser air refrigerated models only Step 7 Install all remaining trim panels M...

Страница 38: ...v 3 Service Manual MCC Hot Cold 2021 Make sure after build in the cool engine is still accessible Keep in mind the complete engine is extendable at the back side of the unit for maintenance and servic...

Страница 39: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 39 6 0 Installation Front door section...

Страница 40: ...ont underframe panel two screws one on each bottom corner Drop In Raise the unit at least 30cm from tabletop level in order to access the screws for the child guard Be careful to support the unit such...

Страница 41: ...ylon washer with collar 1 Glass Nylon washer with collar 2 Step 9 Place hinge on glass door One on the bottom one on top Hight adjustment washer 3701241 and 3701242 For placement washers wait till ste...

Страница 42: ...uck Remove back cover s left and right sliding door stopper Both fixed with three screws Step 15 Place new longer top column cover two screws Re mount side glass holder the first screw Mount second sc...

Страница 43: ...se same screws to mount Place nylon bearing in profile packet in bag with hinge Step 18 Place bumper rubber in bottom profile two Step 19 Place top profile set step 3 in top column cover Step 20 Place...

Страница 44: ...in height yet so they can scratch the bottom plate Always place hight adjustment nylon washer first before placing the bottom hinge pin in its bearing Step 22 Adjust glass door height by adjusting pos...

Страница 45: ...ont underframe panel two screws one on each bottom corner Drop In Raise the unit at least 30cm from tabletop level in order to access the screws for the child guard Be careful to support the unit such...

Страница 46: ...lay a protection or a locked start up Off otherwise Defrost LED Permanently on defrost active Flashing manual or D I activation Off otherwise Alarm LED Permanently on alarm active Flashing alarm ackno...

Страница 47: ...cool for at least 30 minutes Loading the unit Only load products of which the temperature is maximum 4 C 39 2 F The maximum loading height is 50mm 2 inch below the bottom of the shelf air guide above...

Страница 48: ...To unlock the keypad press and hold for at least 3 seconds until the label UnL appears 2 Press and release SET to access the Machine status menu 3 Scroll through the folders with and until you find t...

Страница 49: ...eck all function are working correctly 8 0 1 Control Panel On Off Switches hot unit Heating Lighting 8 0 2 Factory settings The unit is set at 65 C 149 F intake air temperature If required this temper...

Страница 50: ...ain switch is displayed Switch OFF main switch r12 0 for changing the pre installed application Press UP DOWN to scroll through the parameter list Configure the o61 parameter to select a pre installed...

Страница 51: ...he lighting with appropriate switch next to controller 8 2 1 Loading the unit Only place products that have a core temperature of at least 85 C 185 F or above Only with packaged hot products in bags o...

Страница 52: ...nce to keep a daily cleaning pattern from first use onwards Maintenance schedule for users For detailed cleaning instructions refer to User manual chapter 5 Examples Cleaning possibility the top glass...

Страница 53: ...rost cycle 0 min dt Coil drainage time 0 min dFd Allows to select the evaporator probes exclusion during defrost n flag HAL Maximum temperature alarm 10 C LAL Minimum temperatre alarm 30 C tAO Tempera...

Страница 54: ...erval 1 num dOH Defrost start delay time after request 0 min dEt Defrost timeout determines the maximum defrost duration 30 min dSt Defrost end temperature determiend by evaporator probe 4 C dPO Deter...

Страница 55: ...0 min dCO Compressor deactivation delay after door opened 0 min dCd Fans activation delay after door closed 10 secs Pressure switch Pre folder Pen Number of errors allowed for general pressure switch...

Страница 56: ...alibration 2 Pb2 0 C CA3 Calibration 3 Pb3 0 C ddL Display mode during defrost 2 num Ldd Timeout value for display unlick 15 min dro Select C or F 0 num ddd Selection of type of value to be displayed...

Страница 57: ...emperature alarm signal delay time 30 min dCS Deep cooling cycle setpoint 1 C tdC Deep cooling cycle duration 0 min OSP Offset on setpoint 0 5 C OdF Intervention differential correction 4 C dnt Durati...

Страница 58: ...ntial 1 C Fdt Fan activation delay after a defrost cycle 0 min dt Coil drainage time 0 min dFd Allows to select the evaporator probes exclusion during defrost n flag FCO Evaporator fans operating mode...

Страница 59: ...gy saving mode 0 num ESF Night mode activation for fans y flag Cdt Door close time 60 min 10 ESo Cumulative door open time for disabling Energy Saving mode 0 num OSP Offset on setpoint 0 5 C OdF Inter...

Страница 60: ...ut 2 0 num H21 Configurability of digital output 1 1 num H22 Configurability of digital output 2 3 num H23 Configurability of digital output 3 5 num H25 Enable Disable buzzer 0 num H32 Configurability...

Страница 61: ...out voltage 0 V A75 Maximum voltage 270 V d01 Defrost method no no defrost nAt natural no d02 Defrost stop temperature 6 C d03 Defrost Interval 8 hr d04 Max defrost time 30 min d05 Defrost delay at po...

Страница 62: ...nable no A73 Minimum cut in voltage 0 V A74 Minimum cut out voltage 0 V A75 Maximum voltage 270 V d01 Defrost method no no defrost nAt natural no d02 Defrost stop temperature 6 C d03 Defrost Interval...

Страница 63: ...ne R290 Exclusively electrical devices may be used inside the unit that are certified by the applicable ATEX directive The cooling circuit and refrigeration system of the unit must not be damaged This...

Страница 64: ...r by unscrewing two closing screws depending on the version Screws Keep condenser free from dirt and dust clean regularly For cleaning use a long haired soft brush and a vacuum cleaner Be aware not to...

Страница 65: ...certified and qualified persons in a well ventilated environment 10 0 2 Replace the mains cord WARNING Hazardous electrical voltage If the mains cord is damaged it must be replaced by a fully certifi...

Страница 66: ...27 28 50 10 17 96 68 20 12 09 77 25 10 00 Temperature Resistance F C 5 Ohms 4 20 951 14 10 877 32 0 807 50 10 740 68 20 677 77 25 990 10 0 5 Heating element testing Full Serve units Resistance 1 Remov...

Страница 67: ...rm the Alarm icon located in the upper left part will light up To display the active alarm you have to press the set key and look for the AL folder In the following table you will be able to see all t...

Страница 68: ...save the changes Installer parameters When accessed the display will show the first folder e g CP Press and to scroll through the folders on the current level Select the desired folder using set Pres...

Страница 69: ...temperature or the temperature relative to the Setpoint 67 0 320 C F 50 0 50 0 50 0 20 0 50 0 Fdt Fan activation delay after a defrost cycle 0 250 min 0 0 0 0 0 dt Coil drainage time 0 250 min 0 0 0 0...

Страница 70: ...mpressor stops a defrost cycle is performed according to parameter dtY 3 temperature 0 1 2 3 num 1 1 1 1 1 0 1 1 1 0 1 1 dOH Defroststartdelaytimeafterrequest 0 59 min 0 0 0 0 0 0 0 0 0 0 0 0 dEt Defr...

Страница 71: ...int CPS 0 255 min 0 0 0 0 0 0 0 0 0 0 0 0 LIGHTS DIGITALINPUTS Lit folder dOd Enable utility switch off on activation of door switch 0 disabled 1 disables fans 2 disables the compressor 3 disables fan...

Страница 72: ...Ffordisplayingthetemperaturereadbyprobes 0 C 1 F NOTE switching between C and F or vice versa DOES NOT modify the SEt diF values etc e g Setpoint 10 C becomes 10 F 0 1 num 0 0 0 0 0 0 0 0 0 0 0 0 ddd...

Страница 73: ...cordedbyprobePb2 Recordingof labelAd2 infolderAL Alarmiconpermanentlyon waitforthenextdefrostcycleforautomatic return Ad3 endof defrost cycleduetotimeout activation of the defrost for temperature inde...

Страница 74: ...ring connection 5 Air flow not functioning Unit does not reach desired temperature 1 Heating element malfunction HOT unit only 2 Cooling unit malfunction COLD unit only 3 Strong air current along unit...

Страница 75: ...k Resistance refer 6 4 Replace element Check wiring Check power on fans per shelf Replace Air box Power Supply Cooling engine COLD unit Cooling system does not initiate compressor doesn t run Wiring c...

Страница 76: ...Loose sensor Broken Sensor Loose sensor Clean condensor with long haired soft brush Replace sensor Check sensor wiring Replace sensor Check sensor wiring Air out sensor Cold Unit Ice on evaporator The...

Страница 77: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 77 Page intentionally left blank...

Страница 78: ...are of the weight of the glass 2 Remove the air guide for the hot version or the air box for the cold version by simply lifting them out HOT COLD 3 Loosen the adjusting screws which secure the glass w...

Страница 79: ...tirety past the top guide CAUTION Once past the top guide the glass pane might fall if not properly held Hence do not leave it standing upright without being supported by both guide rails or holding i...

Страница 80: ...rsions please select appropriate type In order to replace the sliding doors take following step 1 Remove Sliding door stopper three screws Left and right side 2 Remove rail cover loosen mounting screw...

Страница 81: ...type Recognizable Two screws on top of rail cover Top back side two left and two right In order to replace the sliding doors take following step 1 Remove Sliding door stopper three screws Left and rig...

Страница 82: ...each 2 Lift bottom shelf at the front It is turnable 3 Sensor is located at the back 4 Sensor is screwed from the outside in 5 Remove glass pane from lowest shelf see 11 10 6 Remove fan box see 11 9 7...

Страница 83: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 83 11 6 Sensor Replacement Cold Unit Defrost sensor Under construction Air out sensor Under construction...

Страница 84: ...unting screws 3x of child glass Screwed from underneath 3 Place new child glass 4 Mount in reverse order Mounting screws 11 8 MCC Air guide replacement 1 Air guide replacement 2 For replacement open t...

Страница 85: ...move glass pane clamp 4 or more bolts depending on unit length 3 Remove Glass pane refer 11 10 4 Remove air box 1 connector two screws 5 Replace in reverse order Note If replacement has to take place...

Страница 86: ...ir outlet cover by removing the screws depending on length three or more screws 2 Remove glass mounting profile by removing the screws depending on length three or more screws 3 Lift out glass pane st...

Страница 87: ...some versions you also need to loosen the screws on the side of the under storage compartment After loosening the screws you can remove the panel by pulling it slightly down and then turning it towar...

Страница 88: ...screw top 5 Disconnect connector in Column before you do so make a note of the placing of the red and black cable in the connector 6 Take LED light out of LED light holder and place new LED 7 Connect...

Страница 89: ...ment NEVER make a connection underneath the heating element Connect the wires in the column using a wago connector like the one on this picture Take care of connecting Red to Red Blue to Blue and Yell...

Страница 90: ...2 2 Remove Top glass See 11 1 3 Take out Air guide see 11 8 4 Remove Air box by unscrewing the mounting screws at the back 5 Remove colomn covers left and right back by unscrewing the top and bottom s...

Страница 91: ...3 Replace in reverse order Back panel 1 Remove back panel by removing the holding screws left and right bottom corner Bottom view 2 Pull panel slightly towards you and down to remove 3 Replace in rev...

Страница 92: ...F max 25 C 77 F min 17 C 62 2 F max 25 C 77 F min 17 C 62 2 F max 25 C 77 F Relative Humidity max 60 max 60 max 60 Noise Level at workspace 70 dB A 70 dB A 70 dB A Voltage 1N 230V 1N 230V 1N 230V Fre...

Страница 93: ...ve Humidity max 60 max 60 max 60 Noise Level at workspace 70 dB A 70 dB A 70 dB A Voltage 1N 230V 1N 230V 1N 230V Frequency 50 Hz 50 Hz 50 Hz Max nominal Current 3 9 A 4 2 A 5 2 A Plug 2 pole earthed...

Страница 94: ...1420 mm Weight Net approx 152 kg 335 lbs 179 kg 395 lbs 206 kg 454 lbs Ambient Temperature min 20 C 68 F max 30 C 86 F min 20 C 68 F max 30 C 86 F min 20 C 68 F max 30 C 86 F Relative Humidity max 60...

Страница 95: ...86 F min 20 C 68 F max 30 C 86 F Relative Humidity max 60 max 60 max 60 Noise Level at workspace 70 dB A 70 dB A 70 dB A Voltage 1N 230V 1N 230V 3N 400 230V Frequency 50 60 Hz 50 60Hz 50 60 Hz Max no...

Страница 96: ...475 410 209 250 296 840 1420 480 100 750 600 585 475 410 209 250 296 840 1420 480 100 585 475 410 209 250 296 840 1420 MCC 120 Cold MCC 150 Cold 1200 mm 1500 mm 750 mm 750 mm 1420 mm 1420 mm 1320 mm...

Страница 97: ...00 750 600 585 475 410 209 250 296 840 1420 480 100 750 600 585 475 410 209 250 296 840 1420 480 100 1N 230V 1N 230V 50 Hz 50 Hz 0 56 kW 0 67 kW R290 3 R290 3 MCC 90 Cold drop in version MCC 120 Cold...

Страница 98: ...nical information please visit w MCC 1200 1500 750 600 100 750 600 585 475 410 209 250 296 840 1420 480 100 MCC COLD 012020 www frijado com endment without prior notice tion please visit www frijado c...

Страница 99: ...5 410 243 250 290 840 1420 480 100 750 600 550 475 410 243 250 290 840 1420 480 100 550 475 410 243 250 90 840 20 MCC 90 Hot MCC 120 Hot 900 mm 1200 mm 750 mm 750 mm 1420 mm 1420 mm 1053 mm 1053 mm 1N...

Страница 100: ...al information please 600 900 1200 750 600 100 750 600 550 475 410 243 250 290 840 1420 480 100 750 600 550 475 410 243 250 290 840 1420 480 100 50 Hz 50 Hz 3 02 kW 4 19 kW MCC 60 Hot drop in version...

Страница 101: ...al information please v 900 1200 750 600 100 750 600 550 475 410 243 250 290 840 1420 480 100 MCC HOT 012020 www frijado com MCC 90 Hot drop in version MCC 120 Hot drop in version amendment without pr...

Страница 102: ...Rev 3 Service Manual MCC Hot Cold 2021 MCC placed on wheels will alway need a floor seal as seen on picture in order to prevent warm outlet air being sucked in at the air inlet condensor side back sid...

Страница 103: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 103 Page intentionally left blank...

Страница 104: ...Page 104 Rev 3 Service Manual MCC Hot Cold 2021 13 0 Exploded view MCC Hot Self Serve 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Complete assy 250...

Страница 105: ...lf MCC 60 Rear cover Shelf MCC 90 Rear cover Shelf MCC 120 9384303 9384235 9384304 15 Fan Box Middle MCC 60 Fan Box Middle MCC 90 Fan Box Middle MCC 120 9380072s 9380058s 9380074s See remark serial nu...

Страница 106: ...Page 106 Rev 3 Service Manual MCC Hot Cold 2021 13 0 Exploded view MCC Hot Self Serve 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Complete assy 250...

Страница 107: ...S 60 middle 230V Assy shelf MCC Hot SS 60 large 230V Assy shelf MCC Hot SS 90 small 230V Assy shelf MCC Hot SS 90 middle 230V Assy shelf MCC Hot SS 90 Large 230V Assy shelf MCC Hot SS 120 small 230V A...

Страница 108: ...Page 108 Rev 3 Service Manual MCC Hot Cold 2021 13 0 Exploded view MCC Hot Self Serve 64 65 66 67 68 69 70 71 72 73 75 76 77 78 79 80 81 82 72 300...

Страница 109: ...ding door 120 Right V1 9380226s 9380216s 9380220s 9380210s 9380222s 9380212s 1 1 1 1 1 1 70 Assy Glass sliding door 60 Left Assy Glass sliding door 90 Left Assy Glass sliding door 120 Left 9380217s 93...

Страница 110: ...Page 110 Rev 3 Service Manual MCC Hot Cold 2021 13 0 Exploded view MCC Hot Self Serve 34 36 37 38 39 40 41 42 43 44 45 50 52 46 53 54 55 56 57 58 59 60 53 61 62 55...

Страница 111: ...9384091 50 Led driver EDXe 160 12 054 30007730 52 Box electronics 9384094 53 Strain relief Nut for cable gland 9222076 9222077 54 End Clamp Clip fix 35 5 PHX 9191222 55 Terminal PT 4 GN YE Terminal P...

Страница 112: ...Page 112 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Self Serve 159 160 161 162 163 164 165 166 167 168 169 170 171 173 171 174 175 176 177 178 179 180 181 183 81 182 300...

Страница 113: ...r panel 9384021 1 169 Side panel MCC 9384005 2 see 181 170 Glass Top Shelf 410 mm MCC 90 Glass Top Shelf 410 mm MCC 120 Glass Top Shelf 410mm MCC 150 9382052s 9382056s 9382109s 1 1 1 171 Assy price ra...

Страница 114: ...Page 114 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Self Serve 131 132 133 137 138 139 140 141 143 144 145 146 147 148 149 150 151 150 152 153 156 157 158...

Страница 115: ...EO 9381018 1 138 Sticker Black Elect Sign triangle 3500105 1 139 Data plate 9110810 1 140 Sensor NTC 9381017 141 Sensor NTC 9381017 143 Cover electronics box 9384095 1 144 Din Rail1 9293057 145 End C...

Страница 116: ...Page 116 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Self Serve 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 126 125 127 128 129 130...

Страница 117: ...S 50 30005928 120 Connection tube 9383015 121 Clamp 31 37 2650216 122 Pipe support Armafix 2650252 123 Fluid dryer Danfoss 7650204 1 124 Connection tube 9383014 125 126 Compressor 9381003 1 127 Valve...

Страница 118: ...Page 118 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Full Serve 83 84 85 86 87 88 89 90 91 92 93 95 94 96 97 98 99 100 101 102 103 104 105 106 107 108 109...

Страница 119: ...9382083 9382119 91 Insulation front 9382077 1 92 Inner shell MCC 90 Inner shell MCC 120 Inner shell MCC 150 9384096 9384142 9384219 93 94 Product plateau support MCC 90 Product plateau support MCC 120...

Страница 120: ...Page 120 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Cold Full Serve 159 160 161 162 163 165 166 167 168 169 170 173 176 177 178 179 180 181 183 81 182 164 175 300...

Страница 121: ...e 181 170 Glass Top Shelf 410 mm MCC 90 Glass Top Shelf 410 mm MCC 120 Glass Top Shelf 410mm MCC 150 9382052 9382056 9382109 1 1 1 171 Assy price rail glass shelf MCC 90 Assy price rail glass shelf MC...

Страница 122: ...Page 122 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Hot Full Serve 64 65 66 69 70 71 72 73 74 75 76 77 80 81 82 72 78 67 68 85 83 84 300...

Страница 123: ...ing door 90 Left Assy Glass sliding door 120 Left 9380217s 9380211s 9380213s 1 1 1 71 Back panel MCC 60 Back panel MCC 90 Back panel MCC 120 9384006 9384007 9384008 1 1 1 72 Side glass topside bracket...

Страница 124: ...ge 124 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Hot Full Serve 83 85 86 87 89 90 91 92 93 95 94 96 97 98 99 102 106 107 108 109 L 200 201 202 203 204 205 206 207 208 209 210 211 2...

Страница 125: ...ulation bottom MCC 120 9382076 9382083 9382119 91 Insulation front 9382077 1 92 Inner shell MCC 60 Inner shell MCC 90 Inner shell MCC 120 9384096 9384142 9384219 102 Rosette type 240 1 1 4 9381001 106...

Страница 126: ...Page 126 Rev 3 Service Manual MCC Hot Cold 2021 14 0 Exploded view MCC Hot Full Serve 34 36 37 38 40 41 42 43 44 45 50 52 46 53 54 55 56 57 58 59 60 53 61 62 64 65 66 67 68 69 70 71...

Страница 127: ...5 Led 3000k 12V 400mm MCC 60 Led 3000k 12V 700mm MCC90 Led 3000k 12V 1000mm MCC 120 9382075 9382067 9382068 44 Led Armature support bracket 9384091 50 Led driver EDXe 160 12 054 30007730 52 Box electr...

Страница 128: ...1 24 Glass shelf middle MCC 60 9382036s 2 1 24 Glass shelf middle MCC 90 9382140s 2 1 24 Glass shelf middle MCC 120 9382080s 2 1 28 Heating element 475x540 750W MCC 60 9382090 2 1 28 Heating element 7...

Страница 129: ...0 Left V0 V1 9380215s 73 Side glass MCC 9382030s 2 2 79 Childguard assy MCC60 9380017s 2 1 79 Childguard assy MCC90 9380018s 2 1 79 Childguard assy MCC120 9380019s 2 1 175 Childguard assy MCC 150 9380...

Страница 130: ...p Shelf 410mm MCC 150 9382109s 3 1 171 Assy price rail glass shelf MCC 60 9380146s 3 3 171 Assy price rail glass shelf MCC 90 9380052s 3 3 171 Assy price rail glass shelf MCC 120 9380073s 3 3 Assy pri...

Страница 131: ...8x13 ZP Self drilling and tapping 866 4287620 Screw 4 2x12 NP self tapping 868 4285078 Nut 1 4 bsw ZP 871 9191049 Set screw M5x5 black 872 4285010 Nut M3 ZP with lockwasher Pos Part nr Description 87...

Страница 132: ...M4x20 thread rolling 951 8071043 Nut M4 serrated ZP 952 6962187 953 0197807 Screw M4x30 slotted ZP 954 4285084 Screw 4 8x19 ZP Self drilling and tapping 955 9008217 Blind rivet 4x8 6 956 9174680 Wash...

Страница 133: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 133 16 0 Electrical schematic MCC Hot Self Serve One Phase Schematics for Serial number starting from serial number...

Страница 134: ...Page 134 Rev 3 Service Manual MCC Hot Cold 2021 16 1 Electrical wiring MCC Hot Self Serve One Phase A1 A2 1L1 3L2 5L3 7L4 2T1 4T2 6T3 8T4 N L N L GN 2A 1A 5B 4B 5B 4B 2A 1A...

Страница 135: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 135 16 1 Electrical schematic MCC Hot Self Serve One phase and time relais Schematics for Serial number before serial number...

Страница 136: ...136 Rev 3 Service Manual MCC Hot Cold 2021 N L N L GN 5 6 2A 1A 5B 4B 5B 4B 2A 1A Tijd relais instellen 2m tijdspanne 12 5 tijd BE modus 16 1 Electrical wiring MCC Hot Self Serve One phase and time re...

Страница 137: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 137 16 2 Electrical schematic MCC Hot Self Serve Three phase...

Страница 138: ...Page 138 Rev 3 Service Manual MCC Hot Cold 2021 16 2 Electrical wiring MCC Hot Self Serve Three phase...

Страница 139: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 139 17 0 Electrical schematics MCC Cold Self Serve...

Страница 140: ...Page 140 Rev 3 Service Manual MCC Hot Cold 2021...

Страница 141: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 141 17 1 Electrical wiring MCC Cold Self Serve N L...

Страница 142: ...Page 142 Rev 3 Service Manual MCC Hot Cold 2021...

Страница 143: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 143 17 2 Circuit Diagram MCC Hot Full Serve...

Страница 144: ...Page 144 Rev 3 Service Manual MCC Hot Cold 2021 17 3 Electrical wiring MCC Hot Full Serve...

Страница 145: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 145...

Страница 146: ...Page 146 Rev 3 Service Manual MCC Hot Cold 2021...

Страница 147: ...Rev 3 Service Manual MCC Hot Cold 2021 Page 147 Fri Jado B V Blauwhekken 2 4751 XD Oud Gastel The Netherlands Tel 31 0 76 50 85 400...

Отзывы: