It is reiterated that the condition for matching values 1 and 2 of the refresh or unlock
sequence remains unchanged. The difference for 8-bit accesses is that the criterion for
detecting a mismatch is less strict. Any 16-bit access still needs to adhere to the original
guidelines, mentioned in the sections
24.9 Restrictions on watchdog operation
This section mentions some exceptions to the watchdog operation that may not be
apparent to you.
• Restriction on unlock/refresh operations—In the period between the closure of the
WCT window after unlock and the actual reload of the watchdog timer, unlock and
refresh operations need not be attempted.
• The update and reload of the watchdog timer happens two to three watchdog clocks
after WCT window closes, following a successful configuration on unlock.
• Clock Switching Delay—The watchdog uses glitch-free multiplexers at two places –
one to choose between the LPO oscillator input and alternate clock input, and the
other to choose between the watchdog functional clock and fast clock input for
watchdog functional test. A maximum time period of ~2 clock A cycles plus ~2
clock B cycles elapses from the time a switch is requested to the occurrence of the
actual clock switch, where clock A and B are the two input clocks to the clock mux.
• For the windowed mode, there is a two to three bus clock latency between the
watchdog counter going past the window value and the same registering in the bus
clock domain.
• For proper operation of the watchdog, the watchdog clock must be at least five times
slower than the system bus clock at all times. An exception is when the watchdog
clock is synchronous to the bus clock wherein the watchdog clock can be as fast as
the bus clock.
• WCT must be equivalent to at least three watchdog clock cycles. If not ensured, this
means that even after the close of the WCT window, you have to wait for the
synchronized system reset to deassert in the watchdog clock domain, before
expecting the configuration updates to take effect.
• The time-out value of the watchdog should be set to a minimum of four watchdog
clock cycles. This is to take into account the delay in new settings taking effect in the
watchdog clock domain.
Chapter 24 Watchdog Timer (WDOG)
K22F Sub-Family Reference Manual , Rev. 3, 7/2014
Freescale Semiconductor, Inc.
529
Содержание MK22FN256VDC12
Страница 2: ...K22F Sub Family Reference Manual Rev 3 7 2014 2 Freescale Semiconductor Inc...
Страница 136: ...Human machine interfaces K22F Sub Family Reference Manual Rev 3 7 2014 136 Freescale Semiconductor Inc...
Страница 164: ...Module clocks K22F Sub Family Reference Manual Rev 3 7 2014 164 Freescale Semiconductor Inc...
Страница 246: ...Functional description K22F Sub Family Reference Manual Rev 3 7 2014 246 Freescale Semiconductor Inc...
Страница 328: ...Kinetis Flashloader Status Error Codes K22F Sub Family Reference Manual Rev 3 7 2014 328 Freescale Semiconductor Inc...
Страница 360: ...Functional description K22F Sub Family Reference Manual Rev 3 7 2014 360 Freescale Semiconductor Inc...
Страница 388: ...Functional description K22F Sub Family Reference Manual Rev 3 7 2014 388 Freescale Semiconductor Inc...
Страница 402: ...Initialization application information K22F Sub Family Reference Manual Rev 3 7 2014 402 Freescale Semiconductor Inc...
Страница 500: ...Initialization application information K22F Sub Family Reference Manual Rev 3 7 2014 500 Freescale Semiconductor Inc...
Страница 670: ...Flash memory map for EzPort access K22F Sub Family Reference Manual Rev 3 7 2014 670 Freescale Semiconductor Inc...
Страница 680: ...Functional description K22F Sub Family Reference Manual Rev 3 7 2014 680 Freescale Semiconductor Inc...
Страница 744: ...Application information K22F Sub Family Reference Manual Rev 3 7 2014 744 Freescale Semiconductor Inc...
Страница 784: ...Functional description K22F Sub Family Reference Manual Rev 3 7 2014 784 Freescale Semiconductor Inc...
Страница 794: ...Initialization Application Information K22F Sub Family Reference Manual Rev 3 7 2014 794 Freescale Semiconductor Inc...
Страница 960: ...Example configuration for chained timers K22F Sub Family Reference Manual Rev 3 7 2014 960 Freescale Semiconductor Inc...
Страница 1036: ...Device mode IRC48 operation K22F Sub Family Reference Manual Rev 3 7 2014 1036 Freescale Semiconductor Inc...
Страница 1040: ...USB Voltage Regulator Module Signal Descriptions K22F Sub Family Reference Manual Rev 3 7 2014 1040 Freescale Semiconductor Inc...
Страница 1094: ...Initialization application information K22F Sub Family Reference Manual Rev 3 7 2014 1094 Freescale Semiconductor Inc...
Страница 1128: ...Initialization application information K22F Sub Family Reference Manual Rev 3 7 2014 1128 Freescale Semiconductor Inc...
Страница 1216: ...Application information K22F Sub Family Reference Manual Rev 3 7 2014 1216 Freescale Semiconductor Inc...
Страница 1298: ...Functional description K22F Sub Family Reference Manual Rev 3 7 2014 1298 Freescale Semiconductor Inc...
Страница 1312: ...K22F Sub Family Reference Manual Rev 3 7 2014 1312 Freescale Semiconductor Inc...