manualshive.com logo in svg
background image

Operating Manual Type E

Coffee machine Ecolino

Softwareversion as of:   V 2.05
Revised No.: SL 20987
Date: 01.05.2002, Rev. C
Visum:  BJC

Содержание Ecolino

Страница 1: ...Operating Manual Type E Coffee machine Ecolino Softwareversion as of V 2 05 Revised No SL 20987 Date 01 05 2002 Rev C Visum BJC...

Страница 2: ...u use your new appliance please read the operating instructions carefully and keep them for future reference In particular note the instructions for daily cleaning and care of your appliance If they a...

Страница 3: ...n of coffee products and milky coffee products 16 3 3 2 Preparation of tea or heating of beverages with steam milk and milk foam 16 3 4 Rinse Autorinse 17 3 4 1 Rinse 17 3 4 2 Autorinse 17 3 5 Daily c...

Страница 4: ...1 2 Free Card 34 6 1 3 Cash Card Cash Card Plus 34 6 1 3 1 Preparation of beverages with the Cash Cash Card or Free Card 35 6 1 4 Messages 36 6 1 5 Management Card 36 6 1 5 1 Handling of the Manageme...

Страница 5: ...5 2002 Rev C SL 20 987 BJC page 5 6 4 Waiter Control System 47 6 4 1 General Remarks 47 6 4 2 Selection of product 47 6 4 3 Types of Waiter Control Systems 47 7 ACCESSORIES 48 7 1 Cleaning tablets 48...

Страница 6: ...value 7 Recommendet water hardness 7 German hardness 13 French hardn and filter Chlorine content max 100mg lt Stop valve with nonreturne valve 0 8 6 0 bar Outlet tube 16 x 2000 mm Water outlet Water...

Страница 7: ...rwise the local provisions are binding As option the Ecolino can also be operated without fixed water connection and siphon outlet You will find further information regarding the water tank operation...

Страница 8: ...1 4 Precautions The ambient temperature must not fall below 10 C and must not exceed 40 C The coffee machine must not be cleaned by spraying it with a hose or high pressure cleaner Never place hands...

Страница 9: ...and numbers of items nom type ou mod le no de lot d chantillon ou de s rie vent sources et nombre d xemplaires auf das sich diese Erkl rung bezieht mit der den folgenden Norm en oder normativen Dokum...

Страница 10: ...defined starting motor timeout position within 10 sec Switch off the coffee machine by means of the E M S key Check whether the grounds container has beencorrectly inserted or whether an object is pr...

Страница 11: ...l possible repl watersoftener select product See Section 3 5 Daily cleaning clean The product output is still possible select product There is a fault in the water flow error flowmeter Is coffee being...

Страница 12: ...The wrong Pin Code of the card was input Remove the card remove card from the card reader and try again There is no limit to the number of attempts reading error The chip card was inserted the wrong...

Страница 13: ...riate program automatically switches the machine ON at a certain time During the heat up phase a steam surge occurs every minute IT MUST NOT BE WORKED UNDERNEATH OF THE OUTLETS DANGER OF SCALD The cof...

Страница 14: ...ime has been programmed steam dispensing can be terminated by pressing the tea key again Tea dispensing cannot be preselected 3 1 5 Heating up beverages with steam manual autosteam 1 Immerse the steam...

Страница 15: ...oling unit is recommended 3 2 2 Preparation of Cappuccino White coffee 1 Push outlet to desired height 2 Place cup under the coffee outlet and milk froth unit 3 Select desired product 4 The display sh...

Страница 16: ...e programming several products can be selected steps 3 4 however have to repeated These can be reset or terminated using the Stop key Tea or steam can be dispensed simultaneously 3 3 2 Preparation of...

Страница 17: ...ilk andfrothymilkdevicearerinsed Thisrinsesequencetakesabout15seconds Therinsesequence does not replace daily cleaning as described under Section 3 5 3 4 2 Autorinse If no coffee key is pressed for a...

Страница 18: ...e followed when cleaning with cleaning tablet The Ecolino must remain switched on for cleaning 3 5 1 Automatic cleaning programme for coffee machine only for appliances without CF1 CF2 milk and frothy...

Страница 19: ...een closed the display shows the following after approx 2 seconds clean cleaning tablet 10 Drop in tablet through filling funnel Figure 9 11 Press Clean key Figure 10 clean locked selection 12 The aut...

Страница 20: ...ce a day after closing Replace worn seals in good time Before carrying out the automatical cleaning the cappuccinatore has to be cleaned manually 3 5 2a Manual cleaning of the Cappuccinatore CF1 CF2 F...

Страница 21: ...ied and or place the parts overnight in a little cleaning solution Rinse the partsthoroughlywithfreshwaterandreassemblethevalve Notetheassemblydirectionofthevalve body with pressure spring Now push it...

Страница 22: ...itches back to the operating mode 7 Completely open the door Figure 7 clean open door Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 8 Pull out brewing piston and brewing table using...

Страница 23: ...ress the Clean key Figure 14 clean locked selection 16 The automatic cleaning is started and takes from about 1 min to 6 min depending on the number of programmed cleaning cycles 17 After the end of t...

Страница 24: ...le Remove remaining dirt from the drip tray using a cloth Then rinse the drip tray with water and dry with a cloth Insert the drip grille again If the Ecolino is switched off during cleaning the clean...

Страница 25: ...e disconnected from the power supply and the water supply must be closed If the On Off function is programmed with the Adjust Card customer specific the Adjust Card must be inserted and the E M S key...

Страница 26: ...acked up when the Download Card is inserted into thechipcardreaderforthefirsttime OnsubsequentuseoftheDownloadCard thisautomaticback up no longer occurs 4 2 1 1 Saving coffee machine data on Download...

Страница 27: ...ating plate under the identification no During the input the Stop key is used for increasing the number and the Clean key for reaching the next digit position On subsequent use of the Adjust Card ther...

Страница 28: ...milk quantity for cappuccino 1 Insert Adjust Card 2 Press the or key until the parameter adjust quantity is obtained Select product 3 Select the product to be changed adjust quantity For shift product...

Страница 29: ...cleared 4 The counter readings are cleared by pressing the delete counter Shift key again done After the counter readings have been cleared the user automatically returns to the Adjust level 4 3 1 5...

Страница 30: ...4 04 1997 4 Make the desired day setting with the and keys 5 Press the Shift key set date 14 04 1997 6 Make the desired month setting with the and keys 7 Press the Shift key set date 14 04 1997 8 Make...

Страница 31: ...can be selected Mo Fr The Ecolino automatically switches on and off at the programmed times from Monday to Friday The Ecolino can still be switched on and off manually On Saturdays and Sundays the swi...

Страница 32: ...and cleaned 5 1 3 Control The fresh and sewage water level are controlled by means of floating switches If the fresh water container is empty or the sewage canister filled the display indicates Now th...

Страница 33: ...on see Section 6 1 Cash System Section 6 3 Payment systems and Section 6 4 Waiters accounting 5 2 3 Possible accounting systems Internal Cash System Coin tester CF330 Payment systems U Key prog 108 Le...

Страница 34: ...s The withdrawals made using the Free Card can be insepected using the Management Card 6 1 3 Cash Card Cash Card Plus The Cash Card is a credit card For each withdrawal of a product the programmed pri...

Страница 35: ...Insert Card or Free Card into the card reader credit 20 00 select product 3 Select desired product credit 18 50 The product price is debited from or credited to the presele 1 draw 1 Cash Card the pro...

Страница 36: ...display The user cards Management or Load Card do not have the same installation number as that stored in the Ecolino These cards do not function on this Ecolino Ascertain whether you are using the c...

Страница 37: ...PIN code was incorrectly entered the Management Card must be removed and reinserted Input of the PIN code can now be repeated from point 1 6 1 5 2 Accounting mode YES NO Theprogrammedaccountingsystem...

Страница 38: ...1 Insert the Management Card into the card reader 2 Press the or key until the parameter is obtained change price select product 3 Press product price 1 0 00 In the case of Shift product the Shift ke...

Страница 39: ...or key another parameter can chocolate price now be set select product Adapt the existing Sections 6 1 5 5 6 1 5 10 in relation to newly inserted Section 6 1 5 5 6 1 5 6 Cash Card sales 1 Insert the M...

Страница 40: ...turn over perform shift 5 The Management level is reached by pressing the or key 6 1 5 9 Register Free Card 1 Insert the Management Card into the card reader 2 Press the or key until the parameter is...

Страница 41: ...hip Card loads Chip Card information Enable Chip Cards Disable Chip Cards Change PIN code 6 1 6 1 Handling of the Load Card If the Load Card has not yet been assigned to the Ecopower setting made at t...

Страница 42: ...factor programmed by the service engineer load sum 10 00 6 Press the Shift key to load this amount onto the credit XX XX Cash Card save credit 10 00 done credit 10 00 load sum 00 00 7 Remove the Cash...

Страница 43: ...total loaded amount is displayed and can be cleared 1 Insert the Load Card into the card reader 2 Press the or key until the parameter is obtained chip cards loading turn over XX XX If it is intended...

Страница 44: ...ase chip cards perform shift 3 Press the Shift key remove card The Load Card must be removed insert card cash load 4 Insert the Cash Card into the card reader cash card YES 5 The Cash Card must be rem...

Страница 45: ...After the input the new PIN code is saved to the change pin code Load Card done 6 2 Coin Validator 6 2 1 General remarks Initial situation The Ecopower is ready for operation The cash system can run p...

Страница 46: ...to the payment system To grant function of payment system the Ecopwer must be switched on and the account system has to be activated by the management card which is supplied along with the machine see...

Страница 47: ...Ecopower is ready for operation The cash system can be run parallel to the waiter control In order to operate the cash system the Ecopower has to be switched on and the control system must be activate...

Страница 48: ...5 Scope of delivery 1 packing 100 tablets 7 2 Cleaning agent for milk froth unit CF 1 CF Recommended cleaning agents Sterilisation agent 2 NATRIUMHYPOCHLORIT Article number 1L 301 219 Scope of deliver...

Отзывы: