21
EN
ATTENTION!
It is recommended to periodically check the quality of connections for all gas hoses including the rub-
ber flexible hose (at least once a month or whenever the cylinder is replaced). If there are visible cracks,
damage or other signs of damage, the hose should be replaced with new GOK hose that can be bought
from your dealer or at our website or if it is not possible, then ask your dealer who will recommend you
the hose model and type.
ATTENTION:
Please note that the gas cylinder while installed inside the appliance has to be fastened with a cord
with a carabiners inside the gas cylinder chamber to construction elements with holes.
GV32 MANUAL CONTROL
The user choosing the this appliance receives a device equipped with a GV32 controller. Before opera-
ting the control module, read this manual. Proceedings contrary to the instructions or contrary to the
instructions may result in damage to the gas control system components or the device itself, as well as
to fire, property damage or loss of health.
MANUAL FOR MANUAL CONTROL MODULE GV32.
Firing up the device should follow the instructions below. The GV32 gas control system has been de-
signed to completely eliminate the need for its maintenance and any adjustment. The knobs are not
removable. Disassembly will damage the device. Never attempt to open or damage the valve or any of
its other components in any way.
Firing up the device:
1. Turn the
"ON / OFF Knob A"
knob slightly counterclockwise towards the
IGNITION
position until it
stops. Then press the knob for 5 seconds (the gas will only flow to the control burner).
2. Continue to hold the knob and at the same time turn it further in the
PILOT
position (this activates
the control burner piezo). Hold the knob in this position for another 10 seconds until the control
burner ignites (if the remote control does not light, repeat the procedure immediately while the
knob is pressed).
3. After the control burner has ignited, release the knob and turn it counterclockwise further to the
ON
position (this will also start gas flow to the main burner).
Turning off the device:
1. Turn the
"ON / OF Knob A"
knob clockwise until it stops in the
PILOT
position.
2. Press the knob lightly and continue turning it clockwise from the
PILOT
position to the
OFF
position.
The next procedure of firing up the control burner may be repeated when the thermocouple of the
control burner has sufficiently cooled (the period until it cools down may vary depending on the type
of thermocouple used). After the device is completely turned off, re-lighting is possible after about 1
minute (time needed for the thermocouple to cool down).
Flame / gas flow control:
Flame adjustment is done using the
"Temperature Knob B"
knob.
To adjust the flame and power of the device, manually turn the Temperature
Knob B
counterclockwise
(flame increase) or clockwise (flame reduction). To completely close the gas supply to the main bur-
ner, the
ON / OFF Knob A
must be turned to the
PILOT
position.