background image

13

EN

The manufacturer recommends using decorative elements supplied with the device or in the com-

pany's offer. The FRAM GmbH company is not liable for damages resulting from the use of decorative 

elements other than recommended.

If the decorative elements were not installed before the first installation, then to remove them, the side 

walls and glass of the device should be removed, as shown below.

DECORATIVE GLASS WALLS OPTION

There are two versions of OUTDOORFIRE with a decorative glasses on the walls available in black or 

white version. These can be found under following codes:

For white color:

OUTDOORFIRE W

For black color:

OUTDOORFIRE B

Fig. 7 White and Black Glass Decorative versions

Содержание OUTDOORFIRE B

Страница 1: ...GAS OUTDOOR HEATER OUTDOORFIRE W OUTDOORFIRE B User Manual and Warranty Card EN...

Страница 2: ...S OF THIS MANUAL Read the whole manual and share it with every possible user of the device before using the device Any modifications to this device are strictly forbidden Never attempt to tamper with...

Страница 3: ...3 EN APPLIANCE DIMENSIONS Fig 1 Dimensional drawing of the OUTDOORFIRE W OUTDOORFIRE B heater...

Страница 4: ...ry I3P 30 I3P 37 I3P 50 I3B P 30 I3B P 37 I3B P 50 I3 30 37 Destination countries FI NL RO BE CH CZ ES FR GB GR HR IE IT LT NL PL PT SI SK AT CH DE NL SK BE CY DK EE FR GB GR HU HR IT LT NL NO RO SE S...

Страница 5: ...s for any damage It is very important that the gas control system remains intact and free from any damage The device can be serviced only by a qualified technician with appropriate qualifications Fail...

Страница 6: ...osed to accidental contact with the apppliance If necessary use safety barriers to limit access to the applinace NEVER obstruct THE VENTILATION ROOM OF A GAS CYLINDER Under no circumstances any of sol...

Страница 7: ...pilot burner with the valve Do not use replacement system components other than those installed or supplied by the manufacturer or recommended by your dealer or manufacturer FOR OUTDOORFIRE W and OUT...

Страница 8: ...as well as hot elements of the burner Check the correctness and tightness of the installed gas control control system and the entire gas system of the device To do this you can use soapy water or a d...

Страница 9: ...brakes for easy movement and safe positioning of the device To move the appliance unlock the brakes on the wheels and move the appliance The other way to move the appliance is to slightly lift the ma...

Страница 10: ...precipitation STORING A GAS GARDEN HEATER OUTSIDE THE BUILDING IS ONLY PERMITTED WHEN COVE RING THE RAIN COVER IN ANY OTHER ACCIDENT THE DEVICE SHOULD BE LOCATED IN A PLACE WHICH PROTECTED AGAINST FL...

Страница 11: ...pace from flammable materials objects The space indicated above is the minimum free space from flammable materials unless this is removed by another entry Failure to observe the above clearances free...

Страница 12: ...FOR USE OUTDOORS OR IN AMPLY VENTILATED ARE AN AMPLY VENTILATED AREA MUST HAVE A MINIMUM OF 25 OF THE SURFACE AREA OPEN THE SURFACE AREA IS THE SUM OF THE WALLS SURFACE ARRANGEMENT OF DECORATIVE STONE...

Страница 13: ...ve elements were not installed before the first installation then to remove them the side walls and glass of the device should be removed as shown below DECORATIVE GLASS WALLS OPTION There are two ver...

Страница 14: ...ime needed to cool down the hottest elements of the device is about 60 minutes Do not touch the glass or the upper casing parts within an hour after switching off the device Step 1 Remove the screws t...

Страница 15: ...15 EN Step 3 Tilt the side walls slightly towards you and then lifting them up remove them from the mounting holes Step 4 Loosen the screws of the window clamps and remove the windows...

Страница 16: ...places designated for this Moving them may expose the device to damage due to harmful temperatures or flooding The appliance can only work with the gas control valve supplied with the appliance Connec...

Страница 17: ...17 EN Gas pressure reducer Shut off tilt valve Igniter Thermocouple Interrupter block Burner GV32 controller Control pills Fig 8 Connection diagram for the GV32 manual gas control system...

Страница 18: ...block Fig 9 Connection diagram for the GV60 automatic gas control system Magneto wire Receiver Igniter Sterownik GV60 GV32 controller Steuerer GV32 GV32 Controlador GV60 Control burner Shut off tilt...

Страница 19: ...r damaged or if one of them is missing the device cannot be used until the seals are replaced The valve must remain in the position it is installed at the factory Changing the angle of the valve with...

Страница 20: ...to the gas source only when the heater is turned off and the cylinder valve is turned off Never connect the gas cylinder directly to the appliance without the regulator Before replacing the cylinder m...

Страница 21: ...any way Firing up the device 1 Turn the ON OFF Knob A knob slightly counterclockwise towards the IGNITION position until it stops Then press the knob for 5 seconds the gas will only flow to the contr...

Страница 22: ...er OFF shutting off The operating know is in OFF position The thermo electric flame failure device is close position 1 Ignition The operating knob is in PILOT position The magnet unit is open allowing...

Страница 23: ...uld be carried out on a cooled down device with the gas supply cut off and the power supply disconnected ATTENTION Maintenance of the heater must only be performed by a qualified service technician Th...

Страница 24: ...leaning Check that all air inlets to the combustion chamber are clear If necessary clear the holes Check the combustion chamber for signs of corrosion If necessary remove corrosion and cover the defec...

Страница 25: ...FRAM GmbH Industriestra e 12 22 49324 Melle www fram gmbh de...

Отзывы: