19
EN
Pilot burner
Thermocouple
Piezoigniter
Anti tilt valve
Main burner gas
output
Gas inlet for a gas
hose (has to be
installed with pres-
sure regulator)
Valve operating knob
Fig. 10. Connection diagram for the ASC90 manual gas control system
CONNECTION TO THE GAS SOURCE (GAS BOTTLES/CYLINDERS)
Connect the regulator to the cylinder making sure that the seals are in place (See diagram above), if
the seals are old or damaged or if one of them is missing, the device cannot be used until the seals
are replaced. The valve must remain in the position it is installed at the factory. Changing the angle of
the valve with anti-tilt valve results in closing the gas supply to the device and thus switching it off.
ATTENTION!!!
The anti-tilt valve is a protection against overturning of the appliance, thanks to which in the event
of the appliance overturning, the valve automatically cuts off the gas supply to the controller, which
extinguishes the flame. Below you can see the GOK anti-tilt valve which is preinstalled on the OUT-
DOORFIRE.