4
EN
Model version
Valve
Category
Pressure / Gas
Destination countries
OUTDOORFIRE W
OUTDOORFIRE B
MERTIK
MAXITROL
GV32
I3B/P
30 mbar, G30
BE, CY, CZ, DK, EE, ES, FR, GB,
GR, HU, IE, IT, LT, NL, NO, PT, RO,
SE, SI, SK,
37 mbar, G30
PL
50 mbar, G30
AT, CH, DE, FR, SK
I3P
30 mbar, G31
FI, NL, RO
37 mbar, G31
BE, CH, CY, CZ, ES, FR, GB, GR,
IE, IT, LT, HR, NL, PL, PT, SI, SK
50 mbar, G31
AT, CH, DE, NL
I3+
30 mbar. G30
BE, CY, CZ, DK, EE, ES, FR, GB,
GR, HU, IE, IT, LT, NL, NO, PT, RO,
SE, SI, SK
37 mbar, G31
BE, CH, CY, CZ, ES, FR, GB, GR,
IE, IT, LT, HR, NL, PL, PT, SI, SK
TECHNICAL SPECIFICATION
Technical specification - manual control - GV32 gas blockw
Unit
Appliance category
I
3P(30)
I
3P(37)
I
3P(50)
I
3B/P(30)
I
3B/P(37)
I
3B/P(50)
I
3+(30/37)
Destination
countries
-
FI, NL,
RO
BE, CH,
CZ, ES, FR,
GB, GR,
HR, IE, IT,
LT, NL, PL,
PT, SI, SK
AT, CH,
DE, NL,
SK
BE, CY, DK,
EE, FR, GB,
GR, HU, HR,
IT, LT, NL,
NO, RO, SE,
SI, SK, TR
PL
AT, CH,
DE, FR,
SK
BE,CH, CY,
CZ, ES, FR,
GB, GR, IE,
IT, LT, PT,
SI, SK
Reference gas
-
G31
G31
G31
G30
G30
G30
G30/G31
Nominal connection
pressure
[mbar]
30
37
50
30
37
50
30/37
Gas pressure per
burner for nominal
(maximum) load
23
23
23
17
17
17
Regulati-
on screw
fully
opened
Gas pressure per
burner for minimum
load
7,5
8,0
6,5
5,5
7,0
5,5
12,0/14,0
Nominal (maxi-
mum) heat load,
according to Hs
8,2
8,2
8,2
8,2
8,2
8,2
8,2
Minimal heat load,
according to Hs
4,9
4,9
4,9
4,9
4,9
4,9
4,9
Gas nozzle
[mm]
-
1,65
LPG 1.65
1,65
LPG 1.65
1,65
LPG 1.65
1,65
LPG 1.65
1,65
LPG 1.65
1,65
LPG
1.65
1,65
LPG 1.65