24
EN
No.
Scope
Actions
1
General control
Perform firing up procedure in the heater. Check the operation of
all security systems. Check if the main burner flame burns steadily.
Check that the main burner burns evenly.
2
Windshield
control
Check the glass for cracks
Check the degree of dirt on the glass. Clean the glass if necessary.
3
Control of gas
control system
Check the gas connections for leaks.
Check that the cylinder chamber ventilation is not blocked.
Check that the cables connecting the controller to the receiver are
not damaged.
Check that the gas control system components are not exposed to
high temperatures.
Check that the inner chamber and the elements installed in it are
not exposed to moisture. Check that the connecting cables show no
signs of corrosion.
4
Combustion
chamber control
Check that the control burner is not obstructed by decorative
elements.
Check if the thermocouple is within the control flame. Check whether
the combustion chamber requires cleaning.
Check that all air inlets to the combustion chamber are clear. If
necessary, clear the holes.
Check the combustion chamber for signs of corrosion. If necessary,
remove corrosion and cover the defects with a new layer of fireplace
paint.
Check if the main burner ignites smoothly.
5
Control device
control
Check that the components of the control system are not exposed
to overheating.
6
Decorative
elements
Check if the decorative elements require cleaning.
Check that the decorative elements are not in contact with the glass.
Check if the decorative elements cover the openings venting the
hearth.
Check that the decorative elements have not been damaged.
Checklist:
ENVIRONMENTAL PROTECTION
•
All packaging components in which the gas heater has been supplied should be disposed of in a
manner appropriate to their type.
•
Due to the content of heavy metals, batteries are classified as hazardous chemical waste, so after
using them, they should be thrown into special containers for hazardous waste.
•
If the device is used up again, it must be disposed of. The user is obliged to pass the fireplace to the
appropriate institution dealing in the recycling of this type of equipment.