3.
SET UP INSTRUCTIONS
The blower comes packaged as follows:
•
intake of blower closed for protection.
•
Intake #700 silencer housing and manifold #706
assembled together, but separate from blower.
•
Packet containing #424 gasket, 4 x #904 screws and key
ch13.
3.1
START-UP WITH 90° MANIFILD
For final assembly and to put in operation, proceed as
follows:
1.
Remove the protective plug in intake manifold port.
2.
Place #424 gasket on intake port.
3.
Select the desired orientation (see Fig. 1, Fig. 2, Fig. 3).
4. Place the #706 manifold with the #700 silencer housing on
#424 gasket and seal all the way around with #426 screws
using the key (ch13) as provided.
3.2
START-UP WITHOUT 90° MANIFILD
Using the blower without the 90° manifold (ref. Fig. 4)
1. Disassemble the #706 manifold from the intake housing,
removing the #906 bolts.
2.
Place the #424 gasket on the intake port of the blower.
3.
Place the #700 silencer housing on #424 gasket and seal
all the way around with #904 screws using the key (ch13)
as provided.
GB - 18/49
Fig.1 Fig.2
Fig.3
Fig.4 - Version without 90° manifold
706
424
424
700
904
906