FPI P36D Zero Clearance Direct Vent Gas Fireplace
48
REGENCY OPTIONS
Note: If any maintenance etc. must be
done in the firebox, first remove
the Bay louvers and door.
BAY TRIM
Attach supplied magnets each to the back of
the top and bottom trim pieces, and attach trim
to the top and bottom of Bay door.
4) Open the bottom louver. Pull the Burner ON/
OFF control box from inside the bottom of the
fireplace and position the slots in the bracket
over the 2 screws on the left side of the
bottom louver. Push down to lock into place.
Tighten the screws.
Burner ON/OFF
control box
Screws on louver
bracket
BAY DOOR
The Bay louvers MUST be used
with the Bay glass option.
The optional Bay door is an overlay on the
flush front. The standard flush door and glass
must remain on the unit.
1) Slide the Bay Deflector into the 2 Bay
Deflector brackets in the top of the unit.
2) Hook the top of the bay door over the flush
door flange and swing the bottom against
the bottom flange of the flush door.
3) Secure to the flush door bottom bracket with
2 screws provided.
4) Slide the valve extension knobs onto the
valve knobs.
BAY LOUVERS
1) Install top louver by sliding the two bracket
clips into the brackets located on top of the
bay door. See below. The fitted louver
leaves a small gap between faceplate bot-
tom and louver top.
2) Install bottom louver by sliding the two
bracket clips into the brackets located un-
derneath the bay door. Secure with 1 screw
into each Bottom Louver Mounting Bracket
as per diagram below. Use the bottom hole
in the bracket.
3) Slide the valve extension knobs onto the
valve knobs. Match the correct ext. knob
with the valve knob.
Содержание P36D-LP
Страница 6: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 6 UNIT DIMENSIONS...
Страница 46: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 46 FLUSH BAY DOOR OPTIONS...
Страница 53: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 53 CAST FACEPLATE...
Страница 62: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 62 REPLACEMENT PARTS LIST...