FPI P36D Zero Clearance Direct Vent Gas Fireplace
44
MAINTENANCE
Note: Never operate the appliance with-
out the glass properly secured in
place.
6) Do not use this appliance if any part has
been under water. Immediately call a qual-
ified service technician to inspect the appli-
ance and to replace nay part of the control
system and any gas control which has
been under water.
7) Verify operation after servicing.
General Vent Maintenance
Conduct an inspection of the venting system
semi-annually. Recommended areas to inspect
as follows:
1) Check the Venting System for corrosion in
areas that are exposed to the elements.
These will appear as rust spots or streaks,
and in extreme cases, holes. These com-
ponents should be replaced immediately.
2) Remove the Cap, and shine a flashlight
down the Vent. Remove any bird nests, or
other foreign material.
3) Check for evidences of excessive conden-
sation, such as water droplets forming in
the inner liner, and subsequently dripping
out the joints, Continuous condensation
can cause corrosion of caps, pipe, and
fittings. It may be caused by having exces-
sive lateral runs, too many elbows, and
exterior portions of the system being ex-
posed to cold weather.
4) Inspect joints, to verify that no pipe sections
or fittings have been disturbed, and conse-
quently loosened. Also check mechanical
supports such as Wall Straps, or plumbers'
tape for rigidity.
GOLD-PLATED or
BRASS LOUVERS
The 24 carat gold-plated or brass finish on the
louvers and trim requires little maintenance, and
need only be cleaned with a damp cloth. DO
NOT use abrasive materials or chemical clean-
ers, as they may harm the finish and void the
warranty. Clean any fingerprints off be-
fore turning the unit on.
GOLD-PLATED or
BRASS TRIM
The 24 carat gold plated or brass finish on the
trim requires little maintenance, and need only
be cleaned with a damp cloth. DO NOT use
abrasive materials or chemical cleaners, as
they may harm the finish and void the warranty.
Clean any fingerprints off before turning
the unit on. If the top louvers start to
discolour, check the door gasket seal and
replace if necessary.
LOG REPLACEMENT
The unit should never be used with broken logs.
Turn off the gas valve and allow the unit to cool
before opening door and carefully remove the
logs. (The pilot light generates enough heat to
burn someone.) If for any reason a log should
need replacement, you must use the proper
replacement log. The position of these logs must
be as shown in the diagrams under Log Instal-
lation.
Note: Improper positioning of logs may
create carbon build-up and will
severely alter the unit's perform-
ance which is not covered under
warranty.
THERMOPILE/
THERMOCOUPLE
1) Open the bottom louvers.
2) Loosen the thermocouple or thermopile with
a 7/16" wrench.
3) Disconnect thermocouple by loosening nut
from the valve with a 9mm wrench. Discon-
nect thermopile by loosening 2 screws
marked TP on the valve.
4) Drop the thermocouple or thermopile down
from the bracket and pull it out of the unit.
5) Reinstall the new ones in reverse order.
GLASS GASKET
If the glass gasket requires replacement use 5/
8" flat glass gasket for the Bay Front (Part #
936-243) and a tadpole glass gasket for the
Flush Front (Part # 936-155).
Caution: Wear gloves when removing
damaged or broken glass.
DOOR GLASS
Your FPI fireplace is supplied with high temper-
ature, 5 mm Neoceram ceramic glass that will
withstand the highest heat that your unit will
produce. If your glass requires cleaning, we
recommend using an approved glass cleaner
available at all authorized dealers. Do not use
abrasive materials. Do not clean the glass
when hot.
In the event that you break your glass by
impact, purchase your replacement from an
authorized FPI dealer only, and follow our
step-by-step instructions for replacement.
WARNING: Do not operate the appliance
with the glass panels removed, cracked
or broken. Replacement of the glass
panels should be done by a licensed or
qualified service person.
Flush Glass Replacement
Remove the flush door front. Remove the 4
glass clips from each corner. Slide in the new
replacement glass. Push the 4 glass clips back
onto the frame. The
glass must have
gasketing around
it.
Bay Glass Replacement
1) Remove the door from the unit and place on
a soft surface to prevent scratching.
2) Remove the nuts holding the glass clips in
place and remove.
3) Replace the glass. The glass must have
gasketing around it.
5) Reverse the previous steps, replace the
glass clips and fasten with the nuts but do
not over tighten, as this can break the
glass.
4) Make a periodic check of burner for proper
position and condition. Visually check the
flame of the burner periodically, making
sure the flames are steady; not lifting or
floating. If there is a problem, call a qualified
service person.
5) The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to en-
sure that the flow of combustion and ven-
tilation air is not obstructed.
Содержание P36D-LP
Страница 6: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 6 UNIT DIMENSIONS...
Страница 46: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 46 FLUSH BAY DOOR OPTIONS...
Страница 53: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 53 CAST FACEPLATE...
Страница 62: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 62 REPLACEMENT PARTS LIST...