FPI P36D Zero Clearance Direct Vent Gas Fireplace
41
INSTALLING THE
OPTIONAL FAN
120 Volt AC power is needed for the fan switch
and blower. The fan can be hard wired if
desired. The receptacle box should be installed
on the left hand side of the unit by a qualified
electrician. The neutral (wider) slot of the po-
larized receptacle should be at the top.
Unit must be grounded at all times. Do not
cut the ground terminal off under any
circumstances.
1) Shut the power off.
2) Remove the standard flush door and the
optional bay door, if installed. Open the
bottom louver door.
3) Loosen the 2 screws holding the Burner
ON/OFF switch and bracket to the bottom
louver and lift the assembly out.
4) Turn the fan base on its side (with the base
facing towards you) and then slide the fan
in towards the rear of the unit. Turn the fan
upright and slip it over the two mounting
studs. Take care not to damage the insula-
tion on the fan base. Ensure that the fan
blades do not rub against the valve
tubing. Diagram 1.
5) Connect fan ground cable to ground lug.
Refer to wiring diagram.
6) Slide the thermodisc/cover assembly into
the bracket clip on the underside of the
12) Secure the fan wires and power cord by
attaching one of the adhesive backed wire
holder clips (Part #910-199) onto the stove
base. Use the second clip to bundle up the
wires approximately 4" from the control
box. Ensure that there is no interference
with the wires when the louver is closed
and that no wire will touch the hot metal
surfaces or sharp edges.
13) Plug the fan power cord into the rear end
of the receptacle box to provide the max-
imum clearance from the louvers.
TO REMOVE THE FAN
1) Shut the power off.
2) Reverse the above instructions.
Note: The bearings are lubricated for life.
Do not lubricate them. Make sure you
vacuum the fan area on a regular basis.
IMPORTANT:
These fans collect a lot of dust from
within your home. Ensure you maintain
these fan motors on a regular basis by
vacuuming out the fan blades and hous-
ing using a soft brush nozzle.
firebox. Check that no wire will touch the
hot surfaces. Diagram 2.
7) Attach the Fan control box to the Burner
ON/OFF control box.
Diagram 1
Diagram 2
Use the clip & hook on the side of the
control boxes to join them together.
Secure the 2 boxes together
with one screw.
Hold control box assembly
in place and mark the
position of the right side slot
Secure left
side with 2
screws.
Secure right side with one screw.
8) Secure the two boxes together with one
screw.
9) Position the control box assembly on the
bottom louver and mark the position of the
slot on the right side bracket.
10) Remove the control box as-
sembly and push the hold-down
clip onto the louver. Bend the
tab until it is at 90
o
to the louver.
11) Attach the two control boxes to the bottom
louver and tighten the 2 screws on the left
side and 1 screw on the right side.
INSTALLATION
Содержание P36D-LP
Страница 6: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 6 UNIT DIMENSIONS...
Страница 46: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 46 FLUSH BAY DOOR OPTIONS...
Страница 53: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 53 CAST FACEPLATE...
Страница 62: ...FPI P36D Zero Clearance Direct Vent Gas Fireplace 62 REPLACEMENT PARTS LIST...