21
ENGLIS
H
7.3
Operator troubleshooting
Symptom
Possible cause
Remedy
Section
The machine cannot be
started after switching
on.
Machine not connected
to mains.
Connect the machine to
the mains.
-
Fuse is blown.
Replace fuse below
power switch.
-
A cover is opened.
Close the covers
-
Machine stops with
envelope at insert
position (flap not open).
Envelopes stacked
reversed in the hopper.
Check envelope feed
adjustments. Place
envelopes correctly in
hopper.
Adjustments for
envelope feeding.
Envelope flap sticks.
Store envelopes
according to
specifications.
Specifications.
Wrong envelope type
used (not according
specifications or job
settings).
Change envelopes
according to
specifications.
Specifications.
Envelopes are double
fed.
Envelope separation not
correctly adjusted.
Check separation
settings, adjust if
needed.
Adjustments for
envelope feeding.
Envelopes not placed
properly in the hopper.
Check and replace if
needed.
Adjustments for
envelope feeding.
Envelope stop skewed. Side guides of the
envelope hopper are set
too wide.
Check side guides and
adjust if needed.
Adjustments for
envelope feeding.
Envelopes are fed
irregularly.
Hopper almost empty.
Refill hopper.
Adjustments for
envelope feeding.
Separation set too
narrow.
Check separation
settings, adjust if
needed.
Adjustments for
envelope feeding.
Side guides set too
narrow.
Check side guides and
adjust if needed.
Adjustments for
envelope feeding.
Envelope support not
positioned correctly.
Reposition the envelope
support.
Adjustments for
envelope feeding.
Flap is wrinkled and
sometimes not opened.
Envelope not within
specifications.
Check specifications
and change envelopes if
needed.
Specifications.