Foundry Configuration Guide for the FESX, FSX, and FWSX
A - 4
© Foundry Networks, Inc.
December 2005
Displaying the Syslog Configuration
To display the Syslog parameters currently in effect on a Foundry device, enter the following command from any
level of the CLI:
Syntax:
show logging
The Syslog display shows the following configuration information, in the rows above the log entries themselves.
Table A.2: CLI Display of Syslog Buffer Configuration
This Field...
Displays...
Syslog logging
The state (enabled or disabled) of the Syslog buffer.
messages dropped
The number of Syslog messages dropped due to user-configured
filters. By default, the software logs messages for all Syslog levels.
You can disable individual Syslog levels, in which case the software
filters out messages at those levels. See “Disabling Logging of a
Message Level” on page A-7. Each time the software filters out a
Syslog message, this counter is incremented.
flushes
The number of times the Syslog buffer has been cleared by the
clear
logging
command or equivalent Web management interface option.
See “Clearing the Syslog Messages from the Local Buffer” on page A-
9.
overruns
The number of times the dynamic log buffer has filled up and been
cleared to hold new entries. For example, if the buffer is set for 100
entries, the 101st entry causes an overrun. After that, the 201st entry
causes a second overrun.
level
The message levels that are enabled. Each letter represents a
message type and is identified by the key (level code) below the value.
If you disable logging of a message level, the code for that level is not
listed.
messages logged
The total number of messages that have been logged since the
software was loaded.
level code
The message levels represented by the one-letter codes.
FESX424 Router>
show logging
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 3 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
Static Log Buffer:
Dec 15 19:04:14:A:Fan 1, fan on right connector, failed
Dynamic Log Buffer (50 entries):
Dec 15 18:46:17:I:Interface ethernet 1/4, state up
Dec 15 18:45:21:I:Bridge topology change, vlan 4095, interface 4, changed
state to forwarding
Dec 15 18:45:15:I:Warm start
Содержание FastIron Edge Switch X424
Страница 36: ...Foundry Configuration Guide for the FESX FSX and FWSX 2 12 Foundry Networks Inc December 2005...
Страница 56: ...Foundry Configuration Guide for the FESX FSX and FWSX 3 20 Foundry Networks Inc December 2005...
Страница 70: ...Foundry Configuration Guide for the FESX FSX and FWSX 4 14 Foundry Networks Inc December 2005...
Страница 198: ...Foundry Configuration Guide for the FESX FSX and FWSX 8 38 Foundry Networks Inc December 2005...
Страница 316: ...Foundry Configuration Guide for the FESX FSX and FWSX 12 26 Foundry Networks Inc December 2005...
Страница 334: ...Foundry Configuration Guide for the FESX FSX and FWSX 13 18 Foundry Networks Inc December 22 2005...
Страница 350: ...Foundry Configuration Guide for the FESX FSX and FWSX 15 12 Foundry Networks Inc December 2005...
Страница 458: ...Foundry Configuration Guide for the FESX FSX and FWSX 18 18 Foundry Networks Inc December 2005...
Страница 712: ...Foundry Configuration Guide for the FESX FSX and FWSX 22 32 Foundry Networks Inc December 2005...
Страница 760: ...Foundry Configuration Guide for the FESX FSX and FWSX A 34 Foundry Networks Inc December 2005...
Страница 796: ...Foundry Configuration Guide for the FESX FSX and FWSX C 18 Foundry Networks Inc December 2005...
Страница 820: ...Foundry Configuration Guide for the FESX FSX and FWSX E 10 Foundry Networks Inc December 2005...