Model 8335 (TC/SYNC card) Owner's Manual
25
<NOTE>
When editing to the same time as the external time code, either A-TIME or TC
can be used to match down to second units.
However, if it is to be set in frame units with external time code, frame errors
will be created and thus accurate event start cannot always be expected.
Therefore, in order to operate the recorder more accurately (down to frame
units), use the following method in setup of memory [00].
1
. Set to "IEC MANU" by the SETUP menu "401-***" and likewise use
SETUP menu "402-***" to set the frame rate same as in the external time
code.
2
. Change the display to [TC].
Executing Event Start
1
. Start playback of the external equipment.
At the instant the external time code time and the time set in memory [
00
]
of the first D-15 becomes the same, the D-15 in standby in the STOP or
PAUSE mode will start to playback. At the same time, [
EVENT 0
] is output
from GPI OUT of the first D-15 and the second D-15 will start playback at
the same timing.
6. MEM NO Locate / TIME Locate by TC Time
By installing the 8335, in addition to the time of A-TIME, memory by TC
time, MEM NO locate and time locate then becomes possible.
The actual operating method is the same as when the 8335 is not installed
but before operation, the display must be changed to [
TC
] by the [
DISP TIME
]
key. For operating methods of memory/locate, refer to the D-15 Owners
Manual.
<NOTE>
To execute memory/locate with the TC time, the display must always be
changed to TC. For example, when attempting to locate to the MEM NO stored
in TC time in the memory, if this is executed while A-TIME is displayed, the TC
time for locating will be by the A-TIME and thus be located by this time.