4. Phase Modified Operation by External Sync Signal
Even though time code is not recorded on the tape, the D-15 can be locked
onto external sync signals such as WORD IN, VIDEO IN, AES/EBU digital signals
in phase modified operation.
Interconnections
As shown in the schematic, external sync signals are input to either WORD
IN, VIDEO IN or AES/EBU IN which matches the output of external equipment.
CAUTION
AC IN
CH1
CH2
GPI OUT
37P-REMOTE
GPI IN
CH1
CH2
CH2
CH1
BAL
UNBAL
CH2
CH1
ANALOG INPUT
DIGITAL I/O
OUT
IN
OUT
IN
ANALOG OUTPUT
OUT
IN
THRU
IN
TIME CODE
OUT
IN
OUT
IN
VIDEO
WORD
75
75
OFF
ON
OFF
ON
External equipment
External equipment
AES/EBU signal
External equipment
VIDEO SYNC signal
WORD SYNC signal
Settings Prior to Phase Modified Operation
Any one of the following setups are made depending on type of external
sync signal that is to be input.
<When using WORD IN>
1
. Set the D-15 front panel [
CLOCK
] switch to [
EXT
].
2
. Select "
503-001 (WORD)
" by the SETUP mode "
503-***
" (Selecting the external
sync signal).
When the external sync signal is correctly input, [
EXT CLOCK
] will be lit in
the display.
3
. Set FS to the same FS of the external sync signal which is input.
Set to [
44.1kHz
] or [
48kHz
] with the D-15 front panel [
SAMPLING FREQ
]
switch.