English
8
C-H
Temperature control mode:
REF
REF
Refrigeration.
HEA
Heating.
HYS
1 … 10o
Off / On thermostat differential.
3
CRT
0 … 30 min
Compressor rest time.
2
CT1
0 … 30 min
Thermostat run time with faulty T1 probe.
6
(CT1 = 0 output with faulty T1 will always be on).
CT2
0 … 30 min
Thermostat run time with Faulty T1 probe.
4
(CT2 = 0 & CT1 =>0 output with faulty T1 will always be on).
CSD
0 … 30 min
Compressor stop delay after door has been opened.
1
(Only if DS = YES).
DFM
Defrost start mode:
TIM
NON
Defrost function is disabled.
TIM
Regular time defrost.
FRO
Defrost time elapses only in condition of frost accumulation.
DFT
0 … 99 hours Time interval between defrosts.
6
DFB
Defrost timer clock.
YES
YES
Following mains interruption, timer resumes count.
NO
Following mains interruption, timer restarts from zero.
DLI
-50 … 120o
Defrost end temperature
N/A
Only if T2 = EPO).
DTO
1 … 120 min
Maximum defrost duration.
20
DTY
Defrost type:
OFF
OFF
Timed off cycle defrost (compressor and heater off).
ELE
Electric heater defrost (compressor off, heater on).
GAS
Hot gas defrost (compressor and heater on).
DPD
0 … 240 sec
Evaporator pump down. Timed pause at start of defrost.
0
DRN
0 … 30 min
Drain down period.
2
DDM
Defrost display mode:
DEF
RT
Real (actual) air temperature.
LT
Last temperature display before start of defrost.
SP
The current setpoint value.
DEF
"DEF"
Содержание SLIMLINE FSL400
Страница 16: ...English Slimline High Temp Integeral and Remote Models Wiring Diagram 15...
Страница 17: ...English Slimline Low Meat Temp Integeral and Remote Models Wiring Diagram 16...
Страница 21: ...English Slimline High Temp Integeral Glass Door Models Wiring Diagram Post February 2019 20...
Страница 22: ...English Slimline Low Meat Temp Integeral Wiring Diagram Post February 2019 Models 21...