English
Reg
Para
Min
Mid
Max
Description
C
I
C
NI
O
237
FDS
0 sec
120 sec Minimum evaporator fan stop (following door
opening etc.).
20
20
20
20
20
230
FCM
NON
TIM
TMP
Evaporator fan mode during thermostatic control.
TIM TIM
TIM
TIM
TIM
232
FDT
-120⁰
0⁰
Te-Ta difference for fans to turn off after compres
-
sor stopped. (Only if T2 = EPO and FCM = TMP).
-1
-1
-1
-1
-1
233
FDH
1⁰
120⁰
Temperature differential for evaporator fan restart.
(Only if T2 = EPO and FCM = TMP).
3
3
3
3
3
234
FT1
0 sec
180 sec Fan stop delay after compressor stop.
15
15
15
15
15
235
FT2
0 min
30 min Timed fan stop following FT1. (With FT2 = 0 the
fans remain on all the time).
0
0
0
0
0
236
FT3
0 min
30 min Timed fan run following FT2. (With FT3 = 0 & FT2 >
0 the fans remain off all the time).
2
2
2
2
2
238
ATM
NON
REL
ABS
Alarm threshold configuration.
REL
REL
REL
REL
REL
208
ALA
-50⁰
120⁰
Low temperature alarm threshold.
-2
-2
-2
-2
-2
209
AHA
-50⁰
120⁰
High temperature alarm threshold.
8
8
8
8
8
239
ALR
-12⁰
0⁰
Low temperature alarm differential. (With ALR = 0
the low temperature alarm is excluded).
-5
-5
-5
-5
-5
240
AHR
0⁰
12⁰
High temperature alarm differential. (With AHR = 0
the low temperature alarm is excluded).
5
5
5
5
5
241
ATI
T1
T2
Alarm probe.
T1
T1
T1
T1
T1
242
ATD
0 min
120 min Delay before alarm temperature warning.
90
90
90
90
90
243
ADO
0 min
30 min Delay before door open alarm warning.
8
8
8
8
8
244
AHM
NON
STP
ALR
Operation in case of high condenser alarm
(T2 = CND).
NON NON NON NON NON
210
AHT
-50⁰
120⁰
Condenser alarm temperature (T2 = CND).
65
65
65
65
65
245
ACC
0
weeks
52
weeks
Condenser cleaning period.
(With ACC = 0 condenser cleaning is disabled).
0
0
0
0
0
247
IISM
NON
HDD, DI2
MAN
Switchover method to second parameter set.
HDD HDD HDD HDD HDD
201
IISL
-50⁰
IISH
Minimum limit for IISP setting.
1
-21
1
-21
-2
203
IISH
IISL
120⁰
Maximum limit for IISP setting.
1
-21
1
-21
0
205
IISP
IISL
IISH
Temperature setpoint to be achieved in ‘Mode 2’.
1
-21
1
-21
-2
215
IIHY
1⁰
10⁰
Off / On thermostat differential in ‘Mode 2’.
4
4
4
4
4
231
IIFC
NON
TIM
TMP
Evaporator fan mode during ‘Mode 2’ thermostatic
control.
NON NON NON NON NON
246
HDS
1
5
Controller sensitivity for switch over between
‘Modes’ 1 and 2. (1 = minimum, 5 = maximum).
3
3
3
3
3
222
IIDF 0 hours
99 hours Time interval between defrosts in ‘Mode 2’.
6
6
6
6
6
268.7
SB
NO
YES
Standby button operation.
YES
YES
YES
YES
YES
268.0
DS
NO
YES
Door switch operation
(switch made when door closed).
NO
NO
NO
NO
NO
251
DI2
NON
IISM,
RDS, DS2
HPS
Configurable digital input operation.
NON NON NON NON NON
248
LSM
NON
DOR,
NDR
MAN
Light control mode.
NON NON NON NON NON
13
Содержание SLIMLINE FSL400
Страница 16: ...English Slimline High Temp Integeral and Remote Models Wiring Diagram 15...
Страница 17: ...English Slimline Low Meat Temp Integeral and Remote Models Wiring Diagram 16...
Страница 21: ...English Slimline High Temp Integeral Glass Door Models Wiring Diagram Post February 2019 20...
Страница 22: ...English Slimline Low Meat Temp Integeral Wiring Diagram Post February 2019 Models 21...