Foster SLIMLINE FSL400 Скачать руководство пользователя страница 14

English

Reg

Para

Min

Mid

Max

Description

C

I

C

NI

O

237

FDS

0 sec

120 sec Minimum evaporator fan stop (following door 

opening etc.).

20

20

20

20

20

230

FCM

NON

TIM

TMP

Evaporator fan mode during thermostatic control.

TIM TIM

TIM

TIM

TIM

232

FDT

-120⁰

0⁰

Te-Ta difference for fans to turn off after compres

-

sor stopped. (Only if T2 = EPO and FCM = TMP).

-1

-1

-1

-1

-1

233

FDH

1⁰

120⁰

Temperature differential for evaporator fan restart. 

(Only if T2 = EPO and FCM = TMP).

3

3

3

3

3

234

FT1

0 sec

180 sec Fan stop delay after compressor stop.

15

15

15

15

15

235

FT2

0 min

30 min Timed fan stop following FT1. (With FT2 = 0 the 

fans remain on all the time).

0

0

0

0

0

236

FT3

0 min

30 min Timed fan run following FT2. (With FT3 = 0 & FT2 > 

0 the fans remain off all the time).

2

2

2

2

2

238

ATM

NON

REL

ABS

Alarm threshold configuration.

REL

REL

REL

REL

REL

208

ALA

-50⁰

120⁰

Low temperature alarm threshold.

-2

-2

-2

-2

-2

209

AHA

-50⁰

120⁰

High temperature alarm threshold.

8

8

8

8

8

239

ALR

-12⁰

0⁰

Low temperature alarm differential. (With ALR = 0 

the low temperature alarm is excluded).

-5

-5

-5

-5

-5

240

AHR

0⁰

12⁰

High temperature alarm differential. (With AHR = 0 

the low temperature alarm is excluded).

5

5

5

5

5

241

ATI

T1

T2

Alarm probe.

T1

T1

T1

T1

T1

242

ATD

0 min

120 min Delay before alarm temperature warning.

90

90

90

90

90

243

ADO

0 min

30 min Delay before door open alarm warning.

8

8

8

8

8

244

AHM

NON

STP

ALR

Operation in case of high condenser alarm 

(T2 = CND).

NON NON NON NON NON

210

AHT

-50⁰

120⁰

Condenser alarm temperature (T2 = CND).

65

65

65

65

65

245

ACC

weeks

52 

weeks

Condenser cleaning period. 

(With ACC = 0 condenser cleaning is disabled).

0

0

0

0

0

247

IISM

NON

HDD, DI2

MAN

Switchover method to second parameter set.

HDD HDD HDD HDD HDD

201

IISL

-50⁰

IISH

Minimum limit for IISP setting.

1

-21

1

-21

-2

203

IISH

IISL

120⁰

Maximum limit for IISP setting.

1

-21

1

-21

0

205

IISP

IISL

IISH

Temperature setpoint to be achieved in ‘Mode 2’.

1

-21

1

-21

-2

215

IIHY

1⁰

10⁰

Off / On thermostat differential in ‘Mode 2’.

4

4

4

4

4

231

IIFC

NON

TIM

TMP

Evaporator fan mode during ‘Mode 2’ thermostatic 

control.

NON NON NON NON NON

246

HDS

1

5

Controller sensitivity for switch over between 

‘Modes’ 1 and 2. (1 = minimum, 5 = maximum).

3

3

3

3

3

222

IIDF 0 hours

99 hours Time interval between defrosts in ‘Mode 2’.

6

6

6

6

6

268.7

SB

NO

YES

Standby button operation.

YES

YES

YES

YES

YES

268.0

DS

NO

YES

Door switch operation 

(switch made when door closed).

NO

NO

NO

NO

NO

251

DI2

NON

IISM, 

RDS, DS2

HPS

Configurable digital input operation.

NON NON NON NON NON

248

LSM

NON

DOR, 

NDR

MAN

Light control mode.

NON NON NON NON NON

13

Содержание SLIMLINE FSL400

Страница 1: ...Elizabeth II Suppliers of Commercial Refrigeration Foster Refrigerator King s Lynn Foster Refrigerator Oldmedow Road King s Lynn Norfolk PE30 4JU United Kingdom A division of ITW Ltd Email support fos...

Страница 2: ...information on every variation of this unit neither does it cover the installation or every possible operating or maintenance instruction for the units Health Safety Warnings Information Make sure th...

Страница 3: ...ely from other wastes as they are hazardous to the environ ment refrigerants polyurethane foam and oils 4 When arranging for disposal of waste ensure a waste transfer note or consignment note is compl...

Страница 4: ...L this denotes High or Low temperature units as with a G meaning it has glass doors and M denoting meat Both glass and solid doors are fitted with pivot hinges and also both have magnetic door gaskets...

Страница 5: ...e recorded Displayed only if enabled see configuration parameters Displayed only if ACC 0 User Functions Start Sequence For normal operation Press and hold the button for 3 seconds then release The cu...

Страница 6: ...ximum SPH limit When button i is released the new value is stored Keypad Security Settings The keypad lock avoids undesired potentially dangerous operations which might be attempted when the control l...

Страница 7: ...temperature and defrost SP HYS and DFT The controller will remain operating to the values of these settings unless through monitoring of the air temperature evapora tor temperature and door switch wh...

Страница 8: ...together for 5 seconds The first parameter will show on the display Using the and or buttons select the required parameter Press the i button to display its current value While keeping pressed use the...

Страница 9: ...s only in condition of frost accumulation DFT 0 99 hours Time interval between defrosts 6 DFB Defrost timer clock YES YES Following mains interruption timer resumes count NO Following mains interrupti...

Страница 10: ...pressor is on fans are on When compressor is off fans in accordance to parameters FT1 FT2 and FT3 FDT 120 0o Te Ta difference for fans to turn off after compressor stopped 1 Only if T2 EPO and FCM TMP...

Страница 11: ...ndenser cleaning period 0 With ACC 0 condenser cleaning is disabled IISM Switchover method to second parameter set HDD NON Second parameter set is excluded MAN Second parameter set is activated deacti...

Страница 12: ...itch function operates in series with DS LSM Light control mode NON NON Light output is excluded MAN Light output operation is activated deactivated by button M With OA1 LGT DOR Light output is switch...

Страница 13: ...217 CT1 0 min 30 min Thermostat run time with faulty T1 probe 6 6 6 6 6 218 CT2 0 min 30 min Thermostat off time with faulty T1 probe 4 4 4 4 4 219 CSD 0 min 30 min Compressor stop delay after door h...

Страница 14: ...Alarm probe T1 T1 T1 T1 T1 242 ATD 0 min 120 min Delay before alarm temperature warning 90 90 90 90 90 243 ADO 0 min 30 min Delay before door open alarm warning 8 8 8 8 8 244 AHM NON STP ALR Operatio...

Страница 15: ...0 0 0 250 T2 NON EVP CND T2 probe function NON EVP NON EVP EVP 251 OS2 12 5 C 12 50c T2 probe temperature offset 0 0 0 0 0 252 TLD 1 min 30 min Delay for min TLO and max THI temperature logging 10 10...

Страница 16: ...English Slimline High Temp Integeral and Remote Models Wiring Diagram 15...

Страница 17: ...English Slimline Low Meat Temp Integeral and Remote Models Wiring Diagram 16...

Страница 18: ...English Air and Evaporator Probe Details Diagram Probe Air 2 5M SN4K15H1 00 556284 Probe Evap 2 5M SN4K15H2 00 55627 17...

Страница 19: ...YES YES YES YES DLI 20 20 20 20 20 20 20 20 20 DTO 20 20 20 20 20 20 20 20 20 DTY OFF OFF OFF GAS GAS OFF OFF GAS GAS DPD 0 0 0 0 0 0 0 0 0 DRN 2 2 2 2 2 2 2 2 2 DDM DEF DEF DEF DEF DEF DEF DEF DEF D...

Страница 20: ...4 4 4 4 4 IIFC NON NON NON NON NON NON NON NON NON HDS 3 3 3 3 3 3 3 3 3 IIDF 6 6 6 6 6 6 6 6 6 SB YES YES YES YES YES YES YES YES YES DS YES YES NO YES YES YES NO YES YES DI2 NON NON NON NON NON DS2...

Страница 21: ...English Slimline High Temp Integeral Glass Door Models Wiring Diagram Post February 2019 20...

Страница 22: ...English Slimline Low Meat Temp Integeral Wiring Diagram Post February 2019 Models 21...

Страница 23: ...English Air and Evaporator Probe Details Diagram Probe Air 2 5M SN4K15H1 00 556284 Probe Evap 2 5M SN4K15H2 00 55627 22...

Страница 24: ...itches only displayed if applicable to model and enabled through parameters Compressor will not start No voltage in socket Use voltmeter to check Electrical conductor or wires may be cut Use ohmmeter...

Страница 25: ...purge and recharge Iced up evaporator coil Check temperature control refrigerant charge and defrost mechanism Remove all ice manually and start over Restriction in system Locate exact point of restric...

Страница 26: ...blade Compressor has an internal noise If the noise persists after all other measures have been taken it may be originating from the compressor Loose part s Locate and tighten loose part s Extreme con...

Страница 27: ...ith soap and water Check condition of gasket replace if necessary Dirty condenser coil Clean condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make sure thermostat is not...

Страница 28: ...K Head Office Foster Refrigerator Oldmedow Road Kings Lynn Norfolk PE30 4JU a Division of ITW UK Ltd Tel 44 0 843 216 8833 Fax 44 0 843 216 4707 Email support foster uk com Website www fosterrefrigera...