Foster SLIMLINE FSL400 Скачать руководство пользователя страница 2

English

1

Contents

Manual Information & Health & Safety Notes

1

Enviromental Management Policy

2

Disposal Requirements & Electrical Safety

2

Cabinet Description

3

Controller Relevance Table & Operation

3

User Function

4 to 5

Defrost Operation & Fuzzy Logig

5 to 6

Wiring Diagram for Defrost & Technical Data

7

Confirguration of Parameters

7 to 12

Individual Unit Controller Parameter Values (Pre February 2019 Models Only)

12 to 14

Wiring Diagrams for Pre February 2019 Models & Probe Details

15 to 17

Individual Unit Controller Parameter Values (Post February 2019 Models Only)

18 to 19

Wiring Diagrams for Post February 2019 Models & Probes Details

20 to 22

Troubleshooting & Notes

Service Manual Information:

The products and all information in this manual are subject to change without prior notice.

We assume by the information given that the person(s) working on these refrigeration units are 

fully trained and skilled in all aspects of their workings. Also that they will use the appropriate safety       

equipment and take or meet precautions where required.

The service manual does not cover information on every variation of this unit; neither does it cover the         

installation or every possible operating or maintenance instruction for the units.

Health &Safety Warnings & Information

Make sure the power supply is turned off before making any electrical repairs.

To minimise shock and fire hazards, please do not plug or unplug the unit with wet hands

During maintenance and cleaning, please unplug the unit where required.

Care must be taken when handling or working on the unit as sharp edges may cause 

personal injury, we recommend the wearing of suitable PPE.

Ensure the correct moving and lifting procedures are used when relocating a unit.

Do NOT use abrasive cleaning products, only those that are recommended. Never scour any 

parts of the refrigerator. Scouring pads or chemicals may cause damage by scratching or 

dulling polished surface finishes.
Failure to keep the condenser clean may cause premature failure of the motor/compressor 

which will NOT be covered under warranty policy.

Do NOT touch the cold surfaces in the freezer compartment. Particularly when hands are 

damp or wet, skin may adhere to these extremely cold surfaces and cause frostbite.

 

 

Please ensure the appropriate use of safety aids or Personnel Protective Equipment (PPE) 

are used for you own safety.

Содержание SLIMLINE FSL400

Страница 1: ...Elizabeth II Suppliers of Commercial Refrigeration Foster Refrigerator King s Lynn Foster Refrigerator Oldmedow Road King s Lynn Norfolk PE30 4JU United Kingdom A division of ITW Ltd Email support fos...

Страница 2: ...information on every variation of this unit neither does it cover the installation or every possible operating or maintenance instruction for the units Health Safety Warnings Information Make sure th...

Страница 3: ...ely from other wastes as they are hazardous to the environ ment refrigerants polyurethane foam and oils 4 When arranging for disposal of waste ensure a waste transfer note or consignment note is compl...

Страница 4: ...L this denotes High or Low temperature units as with a G meaning it has glass doors and M denoting meat Both glass and solid doors are fitted with pivot hinges and also both have magnetic door gaskets...

Страница 5: ...e recorded Displayed only if enabled see configuration parameters Displayed only if ACC 0 User Functions Start Sequence For normal operation Press and hold the button for 3 seconds then release The cu...

Страница 6: ...ximum SPH limit When button i is released the new value is stored Keypad Security Settings The keypad lock avoids undesired potentially dangerous operations which might be attempted when the control l...

Страница 7: ...temperature and defrost SP HYS and DFT The controller will remain operating to the values of these settings unless through monitoring of the air temperature evapora tor temperature and door switch wh...

Страница 8: ...together for 5 seconds The first parameter will show on the display Using the and or buttons select the required parameter Press the i button to display its current value While keeping pressed use the...

Страница 9: ...s only in condition of frost accumulation DFT 0 99 hours Time interval between defrosts 6 DFB Defrost timer clock YES YES Following mains interruption timer resumes count NO Following mains interrupti...

Страница 10: ...pressor is on fans are on When compressor is off fans in accordance to parameters FT1 FT2 and FT3 FDT 120 0o Te Ta difference for fans to turn off after compressor stopped 1 Only if T2 EPO and FCM TMP...

Страница 11: ...ndenser cleaning period 0 With ACC 0 condenser cleaning is disabled IISM Switchover method to second parameter set HDD NON Second parameter set is excluded MAN Second parameter set is activated deacti...

Страница 12: ...itch function operates in series with DS LSM Light control mode NON NON Light output is excluded MAN Light output operation is activated deactivated by button M With OA1 LGT DOR Light output is switch...

Страница 13: ...217 CT1 0 min 30 min Thermostat run time with faulty T1 probe 6 6 6 6 6 218 CT2 0 min 30 min Thermostat off time with faulty T1 probe 4 4 4 4 4 219 CSD 0 min 30 min Compressor stop delay after door h...

Страница 14: ...Alarm probe T1 T1 T1 T1 T1 242 ATD 0 min 120 min Delay before alarm temperature warning 90 90 90 90 90 243 ADO 0 min 30 min Delay before door open alarm warning 8 8 8 8 8 244 AHM NON STP ALR Operatio...

Страница 15: ...0 0 0 250 T2 NON EVP CND T2 probe function NON EVP NON EVP EVP 251 OS2 12 5 C 12 50c T2 probe temperature offset 0 0 0 0 0 252 TLD 1 min 30 min Delay for min TLO and max THI temperature logging 10 10...

Страница 16: ...English Slimline High Temp Integeral and Remote Models Wiring Diagram 15...

Страница 17: ...English Slimline Low Meat Temp Integeral and Remote Models Wiring Diagram 16...

Страница 18: ...English Air and Evaporator Probe Details Diagram Probe Air 2 5M SN4K15H1 00 556284 Probe Evap 2 5M SN4K15H2 00 55627 17...

Страница 19: ...YES YES YES YES DLI 20 20 20 20 20 20 20 20 20 DTO 20 20 20 20 20 20 20 20 20 DTY OFF OFF OFF GAS GAS OFF OFF GAS GAS DPD 0 0 0 0 0 0 0 0 0 DRN 2 2 2 2 2 2 2 2 2 DDM DEF DEF DEF DEF DEF DEF DEF DEF D...

Страница 20: ...4 4 4 4 4 IIFC NON NON NON NON NON NON NON NON NON HDS 3 3 3 3 3 3 3 3 3 IIDF 6 6 6 6 6 6 6 6 6 SB YES YES YES YES YES YES YES YES YES DS YES YES NO YES YES YES NO YES YES DI2 NON NON NON NON NON DS2...

Страница 21: ...English Slimline High Temp Integeral Glass Door Models Wiring Diagram Post February 2019 20...

Страница 22: ...English Slimline Low Meat Temp Integeral Wiring Diagram Post February 2019 Models 21...

Страница 23: ...English Air and Evaporator Probe Details Diagram Probe Air 2 5M SN4K15H1 00 556284 Probe Evap 2 5M SN4K15H2 00 55627 22...

Страница 24: ...itches only displayed if applicable to model and enabled through parameters Compressor will not start No voltage in socket Use voltmeter to check Electrical conductor or wires may be cut Use ohmmeter...

Страница 25: ...purge and recharge Iced up evaporator coil Check temperature control refrigerant charge and defrost mechanism Remove all ice manually and start over Restriction in system Locate exact point of restric...

Страница 26: ...blade Compressor has an internal noise If the noise persists after all other measures have been taken it may be originating from the compressor Loose part s Locate and tighten loose part s Extreme con...

Страница 27: ...ith soap and water Check condition of gasket replace if necessary Dirty condenser coil Clean condenser coil Evaporator coil iced over Unplug unit and allow coil to defrost Make sure thermostat is not...

Страница 28: ...K Head Office Foster Refrigerator Oldmedow Road Kings Lynn Norfolk PE30 4JU a Division of ITW UK Ltd Tel 44 0 843 216 8833 Fax 44 0 843 216 4707 Email support foster uk com Website www fosterrefrigera...

Отзывы: