LCD5S Display Icons and Buttons
Indicators and Buttons
Symbol
Reason
Button
Use
Alarm
Info/ Set Point Button
Thermostat
Output
Manual Defrost/ Decrease Button
Fan Output
Increase Button/Manual Activation
Defrost Output
Standby Button
Activation of 2nd Parameter Set
Display & Information Icon
s
During normal operation, the display shows either the temperature measured or one of the following indications:
Symbol
Reason
Button
Use
Defrost In Progress
Condenser high pressure alarm
Controller in Standby
High Temperature Alarm
Condenser clean warning
Low Temperature Alarm
Door open alarm
Probe T1 Failure
Condenser high temperature alarm
Probe T2 Failure
Instant probe 1 temperature
Minimum probe 1 temperature recorded
Instant probe 2 temperature*
Compressor working weeks **
Instant probe 3 temperature*
Keypad state lock
Maximum probe 1 temperature recorded
* Displayed only if enabled (see configuration parameters)
** Displayed only if ACC> 0
User Functions
Start Sequence
For normal operation
•
Press and hold the
button for 3 seconds then release.
The current cabinet temperature will be displayed.
If pressed and held for 5 seconds then released this will start the ‘Test Sequence’
.
The test function is a defined sequence of events that will follow a prescribed pattern (dependent upon parameter values)
that will operate all electrical elements of the system, simulating a short operating pattern. It should enable an engineer to
carryout basic function operations checks of all system parts including refrigeration.
This sequence can take, and the display will count up to, a maximum of 935 seconds before showing ‘
’. The length
of time the test is run will be dependent on the model type and conditions the unit is placed in. After showing ‘
’ the
controller will wait for 1 min, then resume normal operation and show the current temperature of the unit.
To cancel the test sequence prior to completion, press and release
Содержание SLIMLINE FSL400
Страница 16: ...English Slimline High Temp Integeral and Remote Models Wiring Diagram 15...
Страница 17: ...English Slimline Low Meat Temp Integeral and Remote Models Wiring Diagram 16...
Страница 21: ...English Slimline High Temp Integeral Glass Door Models Wiring Diagram Post February 2019 20...
Страница 22: ...English Slimline Low Meat Temp Integeral Wiring Diagram Post February 2019 Models 21...