Management Module LEDs
FortiGate-7060E Management Modules
LED
State
Description
Power
Solid Green
Normal operation.
Blinking Green
Chassis 12V disabled. This means that the administrator has
entered commands into the management module CLI to
power off the PSU main 12V outputs. All fans, FIM and FPM
modules are completely powered off but the management
module is still running.
Red
Chassis 12V enabled but not OK. This means the
management module has enabled the main 12V outputs for
all chassis components, but the power OK (PWOK) signal of
at least one PSU has not been sent. When a PSU is powering
up, it would be normal for this LED to be red for a second
(before PSU outputs are stabilized), but if LED remains red, it
indicates a problem (such as a failed PSU). Management
module or FIM or FPM module voltage sensors would most
likely also trigger alarms if this happens since the PSUs may
not be delivering enough power.
FAN (LEDs for each of
three fan trays)
Off
Fan tachometer sensors disabled. This could happen if the
administrator disabled them from the management module
CLI.
Green
The fan tray is operating normally.
Blinking Red
The fan tray is not working. Chassis cooling may be sufficient
but redundancy is lost and the fan tray that is not working
should be replaced.
Red
A fan tachometer sensor in this fan tray has registered an
alert because a critical or non-recoverable (NR) threshold has
been crossed.
PSU (LEDs for each of
four PSUs)
Off
The PSU is not installed in the chassis.
Green
The PSU is present and operating normally.
Blinking Red
The PSU module is installed but no power is being delivered
(not plugged in).
Red
The PSU's sensors have detected an alert condition. The
PSU's analog sensors crossed critical or non-recoverable (NR)
thresholds, or the PSU Status Failure bit has been set.
27
FortiGate-7060E System Guide
Fortinet Technologies Inc.