Страница 1: ...PSA7000 Hardware Guide Pu ub blish he ed Da at te September 2017 Document Revision 2 0...

Страница 2: ...ut notice Pulse Secure LLC assumes no responsibility for any inaccuracies in this document Pulse Secure LLC reserves the right to change modify transfer or otherwise revise this publication without no...

Страница 3: ...r Rating 15 Environmental Requirements 16 Component Specifications 16 Mounting Rails 17 Where to Get Replacement Components 17 Console and Initial Configuration 18 Connect Console and Network 18 Power...

Страница 4: ...ns 32 Electrical Safety 32 General Safety 33 Installation Instructions 36 Circuit Breaker 37 Power Disconnection Warning 38 Equipment Installation 41 Restricted Area 42 Redundant Power Supplies 44 Bac...

Страница 5: ...ontrol and two rear hot swappable drivebays Below is the front and rear view of the system The disk drives HDD1 and HDD2 and power supplies PWR1 and PWR2 are accessible from the rear For added system...

Страница 6: ...r supply to the server system Turning off the system power with this button removes the main power but keeps a standby power supplied to the system Therefore you must unplug the system before servicin...

Страница 7: ...vity when flashing NIC2 GLAN2 Unused Will always be off HDD Indicates IDE channel activity or SATA drive activity when flashing Power Indicates the power is being supplied to the system power supply T...

Страница 8: ...speed of the connection LED Color Description Activity Yellow flashing Active Link Off No connection Amber 1 Gbps speed Green 100 Mbps speed INT and EXT Port LEDs The PSA7000C has four INT EXT copper...

Страница 9: ...eed LED Color Description Activity Blinking green Activity Link Yellow 1 Gbps link speed Green 10 Gbps link speed Beeping and Alarms Beep Code Description 5 short beeps 1 long beep every 5 seconds No...

Страница 10: ...s a SATA drive failure If one of the SATA drives fail you should be notified by your system management software Note The unit will only support two HDDs The unit will not recognize the third drive if...

Страница 11: ...single press of those buttons will change to Menu mode and load the default menu selection see Menu mode designs If the user presses the Cancel button the LCD immediately changes back to Display mode...

Страница 12: ...is either set to NORMAL or shows a label that describes an error condition If all systems are functioning normally then the LCD shows NORMAL The second line in the NORMAL state is used to show whethe...

Страница 13: ...s If more than one error condition is detected all error conditions will be displayed in sequence with a two seconds pause before switching to the next one All error conditions are cleared prior to re...

Страница 14: ...into the Menu mode Pressing the Right and Left arrows keys cycles through the available system configuration data starting with the Internal IP and going clockwise Pressing Cancel at any point exits...

Страница 15: ...dth 17 2 inches 43 7 cm Height 3 5 inches 8 9 cm Depth 17 7 inches 45 cm Weight 30 lbs 13 6 kg Power Rating The system supports redundant power supplies dual FRU and the maximum power rating is given...

Страница 16: ...5 PSA7000f 2 Dual port 1G 10G Ethernet Intel 82599ES 4 x SFP External I O ports 1x console RJ 45 port 1x10 100 1000 management port Cooling 4x 4cm counter rotating fans The PSA7000f model offers SFP i...

Страница 17: ...secure storage and use To set up your rack follow the step by step instructions included in this manual Where to Get Replacement Components Although not frequently you may need replacement parts for y...

Страница 18: ...nnect the RJ45 end of the cable to the appliance port labeled CONSOLE and the DB9 end to a laptop Additionally connect a network cable from the INT port on the appliance to a switch port 3 On the lapt...

Страница 19: ...indicate that the power supply is functioning normally Ignore error indicators that appear during the first 60 seconds Configure Basic Settings When you boot an unconfigured PSA7000 you need to enter...

Страница 20: ...dress of the internal port you configure the external port through the administrator Web console after initial configuration Network mask Default gateway address Primary DNS server address Secondary D...

Страница 21: ...nect Secure or Pulse Policy Secure builds later Do this to change the personality 1 Start a console session 2 Select option 4 System Operations 3 Select option 5 Factory reset 4 Enter the number corre...

Страница 22: ...in page enter the administrator username and password you created earlier Then click Sign In The administrator Web console opens to the Overview page Licensing the System After you install the device...

Страница 23: ...e screws that looks like this Rack Mounting The box your chassis was shipped in should include two sets of rail assemblies two rail mounting brackets and the mounting screws you will need to install t...

Страница 24: ...ature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipment in an environment compatible with the manufact...

Страница 25: ...he PSA7000 Step 1 Identify the Parts There is a left and right rail assembly for the PSA7000 as marked by the L and R stickers on the inner rails Each assembly has 3 parts inner rail middle rail and o...

Страница 26: ...tabs on the side of the chassis slide into the rails Press down hard on the area shown in the picture then slide the inner rail forward pushing firmly until it clicks into the locked position Step 4 A...

Страница 27: ...into the middle rails As you re sliding it press the locking tabs down on both sides of the chassis The rails will lock into place Note You may require two people to safely mount the chassis Step 6 Bo...

Страница 28: ...al from the chassis These carriers also help promote proper airflow for the drive bays Warning Except for short periods of time swapping hard drives do not operate the server with the hard drives empt...

Страница 29: ...n light indicates that the power supply is operating The PSA7000 chassis includes a redundant power supply Power supplies can be replaced without powering down the system Replacement units can be orde...

Страница 30: ...has qualified SFP Cable combinations Short Range 850 nm and offers them for sale as an optional accessory Check the Price book for the SKUs Customers can either purchase this option from Pulse Secure...

Страница 31: ...able below Brand Length Finisar Juniper transceiver 15 meters Avago transceiver 15 meters PSA7000c This appliance offers dual and redundant 10G network interface ports 4 ports total in the RJ45 form f...

Страница 32: ...safety precautions should be followed to protect yourself from harm and the system from damage Be aware of the locations of the power on off switch on the system as well as the room s emergency power...

Страница 33: ...d into grounded electrical outlets Use a grounded wrist strap designed to prevent static discharge General Safety Keep the area around the system clean and free of clutter While working on the system...

Страница 34: ...quier equipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar...

Страница 35: ...chamelijk letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de...

Страница 36: ...or dem Anschlie en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Av...

Страница 37: ...A 250 V 20 A 250V 20A 250V 20A Warnung Dieses Produkt ist darauf angewiesen dass im Geb ude ein Kurzschluss bzw berstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtu...

Страница 38: ...er Disconnection Warning Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or...

Страница 39: ...itar componentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour install...

Страница 40: ...d and qualified personnel should be allowed to install replace or service this equipment Warnung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal...

Страница 41: ...eerd vervangen of hersteld door geschoold en gekwalificeerd personeel Restricted Area Warning This unit is intended for installation in restricted access areas A restricted access area can be accessed...

Страница 42: ...enerse acceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r s...

Страница 43: ...ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse t...

Страница 44: ...g Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje...

Страница 45: ...ebruik is Voorzichtigheid is geboden tijdens het onderhoud Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes Wa...

Страница 46: ...stall conform ment aux normes lectriques nationales et locales Waarschuwing Product Disposal Warning Ultimate disposal of this product should be handled according to all national laws and regulations...

Страница 47: ...mis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Waarschuwing De uiteindelijke verwijdering van dit product dient te ges...

Страница 48: ...dtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le blo...

Страница 49: ...gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law ver...

Страница 50: ...ur tous les autres appareils lectriques que les produits d sign s par Pulse Secure seulement AC AC UL CSA UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij het inst...

Страница 51: ...Hardware Guide 2017 Pulse Secure LLC All rights reserved 52 Certification Statements Japan A VCCI A Israel Saudi Arabia Complies with the CITC Technical Specification CITC GEN001 IT001 South Korea A...

Страница 52: ...PSA7000 Hardware Guide 2017 Pulse Secure LLC All rights reserved 53 Thailand...