FortiGate-7060E System Guide

7000

Содержание FortiGate-7060E

Страница 1: ...FortiGate 7060E System Guide 7000...

Страница 2: ...t FORTIGATE COOKBOOK http cookbook fortinet com FORTINET TRAINING SERVICES http www fortinet com training FORTIGUARD CENTER http www fortiguard com FORTICAST http forticast fortinet com END USER LICEN...

Страница 3: ...e chassis 13 Hot Swapping an AC PSU 13 DC Power Supply Units PSUs and supplying DC power to the chassis 14 Crimping guidelines 15 Connecting a FortiGate 7060E PSU to DC power 16 Hot Swapping a DC PSU...

Страница 4: ...hassis module from the SMC SDI CLI 32 Comlog 32 System event log SEL 34 Sensor data record SDR 34 Common management module CLI operations 35 Cautions and Warnings 39 Environmental Specifications 39 Sa...

Страница 5: ...an Ethernet connection as well as two switchable console ports that provide console connections to the modules in the chassis slots The active management module controls chassis cooling and power man...

Страница 6: ...nel interfaces B1 to B8 These interfaces are connected to 40Gbps networks Using 40GBASE SR4 multimode QSFP transceivers each QSFP interface can also be split into four 10GBASE SR interfaces and connec...

Страница 7: ...Fan Tray 2 Fan Tray 3 Chassis Ground Connector Registering your FortiGate 7060E chassis FortiGate 7000 series products are registered according to the chassis serial number You need to register your c...

Страница 8: ...agement module and MGMT1 is inactive The active management module always has the IPMB address 0x20 and the inactive management module always has the IPMB address 0x22 The active management module comm...

Страница 9: ...acable If a management module fails you must RMA the chassis The chassis will continue to operate with one or no operating management modules l Four Power Supply Units PSUs installed in the front of t...

Страница 10: ...al AC PSUs l Additional FAN trays l Air Filter kit l FPM and FIM blank panels to be installed in empty chassis slots Physical description of the FortiGate 7060E chassis The FortiGate 7060E chassis is...

Страница 11: ...low and minimum clearance The FortiGate 7060E chassis contains three hot swappable cooling fan trays installed in the back of the chassis Each fan tray includes two fans that operate together When the...

Страница 12: ...re there is enough clearance for effective cooling air flow The following diagram shows the cooling air flow through the chassis and the locations of fan trays Make sure the cooling air intake and war...

Страница 13: ...ate 7060E front panel on page 5 for locations of the PSUs All PSUs should be connected to AC power To improve redundancy you can connect each power supply to a separate power source Use a C15 Power ca...

Страница 14: ...ly is a backup power supply and provides 3 1 redundancy You can add a 5th power supply to provide a second backup power supply and 3 2 redundancy You can add a 6th power supply to provide a third back...

Страница 15: ...should be replaced Crimping guidelines To connect the PSUs to data center power you should use 8 AWG or larger wires depending on the wire length and the power requirements of your chassis The ends o...

Страница 16: ...To connect a PSU to DC power 1 Attach the ESD wrist strap to your wrist and to an ESD socket or to a bare metal surface on the chassis or frame 2 Make sure that the PSU and power cords are not energi...

Страница 17: ...the FortiGate 7060E chassis to ground The FortiGate 7060E chassis includes a ground terminal on the rear the bottom of the FortiGate 7060E back panel The ground terminal provides two connectors to be...

Страница 18: ...rating correctly the LEDs on the PSUs and fans should be lit As well the LEDs on the FortiGate 7060E management module should be lit When the chassis first starts up you should also hear the cooling f...

Страница 19: ...mperature of the rack environment may be greater than room ambient temperature Make sure the operating ambient temperature does not exceed the manufacturer s maximum rated ambient temperature The Fort...

Страница 20: ...es Front Mounting Bracket Front Cable Management Bracket Left Cable Management Bracket Right Cable Management Bracket M4x8 large head pan head screws M4x8 large head pan head screws M4x8 flat head scr...

Страница 21: ...ckets as shown below Make sure you install the tray with enough space above it for the chassis The length of the tray sides adjusts to match your rack Once the 4 post rack mount tray has been installe...

Страница 22: ...d the chassis to the rack Mounting the chassis in a 2 post rack Left Mid Mount Tray Attach to the Rack First M4x6 flat head screws M4x6 flat head screws Right Mid Mount Tray Attach to the Rack First L...

Страница 23: ...fully engaged with the backplane and secured You must also make sure that the sliding latches are fully closed by gently pushing them down The handles must be closed the retention screws tightened and...

Страница 24: ...l The console connect feature status enable or disable FortiGate 7060E management module front panel Status Alarm Temp Power LEDs Fan and PSU power supply LEDs MGMT Ethernet Interface Console 1 Conne...

Страница 25: ...ment module failure If one or both of the management modules fails you should RMA the chassis The chassis and the modules in it will continue to operate with one or no functioning management modules u...

Страница 26: ...een All temperature sensors indicated acceptable operating temperatures Blinking Green At least one temperature sensor is detecting a high temperature outside of the normal operating range In this cas...

Страница 27: ...ely also trigger alarms if this happens since the PSUs may not be delivering enough power FAN LEDs for each of three fan trays Off Fan tachometer sensors disabled This could happen if the administrato...

Страница 28: ...mean that conditions are close to being outside of the allowed operating range For example the temperature is close to exceeding the allowed operating temperature A critical threshold can also be an...

Страница 29: ...S CLIs the new destination is displayed in the terminal window If you press Ctrl T after connecting to the FPM module in slot 6 the console is disconnected Press Ctrl T again to start over again at sl...

Страница 30: ...d with your chassis to Console 1 and to your PC or other device RS 232 console port 2 Start a terminal emulation program on the management computer Use these settings Baud Rate bps 9600 Data bits 8 Pa...

Страница 31: ...command over an Ethernet connection sudo ipmitool I lanplus H 10 160 19 30 k gkey U username P password lan set 4 ipaddr 172 20 120 30 Use the following IPMI commands to change the management module...

Страница 32: ...m Use the following command to power off the module in slot 4 fru deactivate 4 Use the following command to power on the FIM module in slot 2 IPMI address 0x84 fru activate 0x84 Use the following IPMI...

Страница 33: ...00000 Log End 0x00000C37 Log Size 3127 Bytes Display a module s comlog Available on the passive module comlog getinfo slot comlog print slot fortinetoem comlog getinfo fortinetoem comlog print Clear a...

Страница 34: ...SEL time time set yyyy mm dd hh mm ss sel time set Sensor data record SDR The sensor data record SDR contains static information about the sensors in each chassis module Information includes the Sens...

Страница 35: ...e module exit followed by Ctrl R N A Display all commands Available on the passive module help help Display information about all SMC firmware in the chassis info mc info Display SMC device ID Build D...

Страница 36: ...get sel time get Set the management module time Available on the passive module time set yyy mm dd hh mm ss sel time set yyy mm dd hh mm ss Synchronize all module SMC times time sync N A List manageme...

Страница 37: ...ry of users N A user summary User test command N A user test Display the management module serial interface settings Available on the passive module serial print N A Set the SDI baud rate Available on...

Страница 38: ...for RCMP lan set channel ipaddr ip netmask lan set channel macaddr mac lan set channel defgw ipaddr ip lan set channel defgw macaddr mac lan set channel kgkey value lan set channel krkey value lan set...

Страница 39: ...mised Ventilation r duite Installation de l quipement dans un rack doit tre telle que la quantit de flux d air n cessaire au bon fonctionnement de l quipement n est pas compromise Mechanical Loading M...

Страница 40: ...pment intended for installation in Restricted Access Location Avertissement Le mat riel est con u pour tre install dans un endroit o l acc s est restreint Warning A readily accessible disconnect devic...

Страница 41: ...hment plug This separate protective earthing terminal must be permanently connected to earth with a green with yellow stripe conductor minimum size 6 AWG and the connection is to be installed by a qua...

Страница 42: ...a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense WARNING Any changes or modifications to this product n...

Страница 43: ...Regulatory Notices Voluntary Control Council for Interference VCCI Japan Product Safety Electrical Appliance Material PSE Japan PSE Bureau of Standards Metrology and Inspection BSMI Taiwan China A 43...

Страница 44: ...Regulatory Notices China FortiGate 7060E System Guide Fortinet Technologies Inc 44...

Страница 45: ...inet enters a binding written contract signed by Fortinet s General Counsel with a purchaser that expressly warrants that the identified product will perform according to certain expressly identified...