JSC FORTEZA FORTEZA TRIBO-M
Please visit our internet sites:
Page 5
Table 1.1 continued
OEF
Description
Value
One-man movement,
movement of several people
(from 3 to 5 men) and big
animals
Distance to the guarded zone
0.5 m
Driving of wheeled, full-track
and electric-battery vehicles
Distance to the guarded zone (working on LF)
Distance to the guarded zone (working on HF)
1.5 m
6 m
Railway freight and passenger
Distance to the guarded zone (working on LF)
Distance to the guarded zone (working on HF)
15 m
45 m
Power lines (up to 500kV)
Distance to the guarded zone
5 m
Exposure to the radar
electromagnetic field
Is not regulated (with a signal-processing unit installed in the
metal alarm cabinet)
Exposure to the ultra-short
pulses of the electromagnetic
field
Is not regulated (with a signal-processing unit installed in the
metal alarm cabinet)
Exposure to the momentum
neutron flux
Is not regulated
Influence of birds and small
animals over the fence
components:
-
birds
-
small animals
Weight
1 (5) kg
up to 20 kg
1.3. Technical characteristics
THE MAIN TECHNICAL CHARACTERISTICS:
-
The maximum length of the sensitive element (
Forteza sensitive element
) in a single zone up to 300 m;
-
The maximum length of the non-sensitive element (
Forteza non-sensitive element
) in a single zone up to
300 m;
-
Entrance areas 4 independent zones;
-
Relay outputs 4 independent outputs;