JSC FORTEZA FORTEZA TRIBO-M
Please visit our internet sites:
Page 27
13)
Contact NC (normally closed) the target relay – INPUT 2/ZONE2
14)
Contact NC (normally closed) the target relay – INPUT 3/ZONE3
15)
Contact NC (normally closed) the target relay – INPUT 3/ZONE3
16)
Contact NC (normally closed) the target relay – INPUT 4/ZONE4
17)
Contact NC (normally closed) the target relay – INPUT 4/ZONE4
18)
TAMPER - box tamper's contact NC (normally closed)
19)
TAMPER - box tamper's contact NC (normally closed)
20)
To connect zone 3 element shield
21)
To connect zone 3 central elements
22)
To connect zone 4 element shield
23)
To connect zone 4 central elements
CAUTION.
Be sure to ground the guard alarm only at one point - by a fastener on the SPU case.
In mounting the connecting element, sensitive element and end sleeve, be sure to eliminate the
possibility of grounding at other points of electric circuit.
Check the conductors’ polarity in connecting the supply line.