50
12. Pull the swab across the upper laser window in a single direction to clean the surface.
Repeat this multiple times, making sure to cover the full width and length of the upper laser
window while wiping in a single direction.
13. Wait five minutes for the ethanol to evaporate before
inspecting the upper laser window or reinstalling the
optical cassette.
14. Using the telescoping mirror, visually verify the upper
laser window is clean and clear of obstruction. If
there are streaks or debris on the upper laser
window, repeat this cleaning procedure with a new
polyester cloth swab.
15. Loosen the thumb screw in the front-center of
the ceiling of the print enclosure. The optical tray
drops down.
16. Return a clean optical cassette to the cassette tray.
17. Return the cassette tray to its closed position and tighten the thumb screw until it fully
engages.
18. Close the print enclosure door. Press firmly to ensure that the door is fully latched. If necessary,
squeeze the door shut using the cutout on the right side of the printer for leverage.