![formlabs Fuse 1 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/formlabs/fuse-1/fuse-1_manual_2320173022.webp)
20
If a localized fire develops either inside or outside of the machine, immediately take the
following actions.
If the fire is inside the print enclosure:
1. Immediately disconnect the machine from its power source.
2. Open the filter door and locate the emergency chamber door release cable. Pull the cable
away from the machine until the print enclosure door unlocks.
3. Use an ABC fire extinguisher to cover the affected area generously.
If the fire is too large to control:
4. Immediately leave the area and close the door of the room behind you.
5. Evacuate the building according to your organization’s emergency protocols.
6. Call emergency services once you have reached a safe distance from the fire.
3.5.2
Ethanol
When handling ethanol, always consult the safety data sheet (SDS) from the ethanol
supplier as the primary source of information. Handle ethanol with gloves in a well-
ventilated area. Keep away from heat, sparks, and open flame. Ethanol evaporates
rapidly, so keep the rinse tub and bottles closed whenever possible.
3.5.3
Powder
I/n an emergency involving powder, always refer to the safety data sheet (SDS) and/or
seek help from a medical professional.
WARNING