Formica Intentek Скачать руководство пользователя страница 3

Formica Group Technical Guide

   |   3

FTB-0918  |  Rev 2  |  6/20

TECHINCAL GUIDE USE & CARE, WARRANTY, AND INSTALLATON GUIDE 

INTENTEK

™ 

WIRELESS CHARGING SURFACE 

WPC, QI AND QI CERTIFICATION

Qi (pronounced “chee”) is the predominant standard for wireless 
charging. The standard is governed by the Wireless Power 
Consortium (WPC) which has more than 575 member companies. To 
date, more than 500 million Qi enabled receivers have been shipped.

Qi Certified products have passed rigorous, independent laboratory 
tests for safety, interoperability, energy efficiency and quality. To be 
certified, they must work with all Qi wireless products regardless 
of brand or manufacturer. Qi certification ensures that devices (the 

power receivers) and chargers (the power transmitters) always 
worktogether for simple and easy charging.

INCORPORATION OF INTENTEK

 WIRELESS 

CHARGING SURFACES INTO FURNITURE DESIGN: 

TIPS & BEST PRACTICES

Location of the charging zones will vary from project to project. 
The following points represent tips and best practices that should 
be considered for placement of the charging zones only. Formica 
Group is not responsible and assumes no liability for the design, 
engineering, installation, assembly or structural integrity of the 
fabricated piece.
•  Cavity for electronics module must be at least 1" from all 
 

edges of table/top. 

•  Blower direction can point up, down, left, or right  
 

(at 90°, 180°, 270°, or 360°). 

•  Blower inlet and outlet cannot be covered by pedestal, leg, or 
 

other obstruction. 

•  When placing charging zones near each other, we recommend  ..
 

at least 11" is left between center points of the charging icons. 

 

The electronic module casing must be at least 1" apart.

•  When placing two electronics modules near each other, a 
 

blower inlet must be at least 8" from another blower’s outlet. 

 

This rule is to be followed only if blower inlet and outlet are 

 

designed to be near each other.

•  If Intentek

 System is going to be used in an enclosed counter 

 

(i.e. on top of a cabinet or drawer), the enclosed space must 

 

be properly vented. Vent determination is the responsibility 

 

of the furniture designer. Venting must be sufficient to support

 

 

the blower at 2CFM. 

•  Electronics module cannot be in direct contact with 
 

obstructions: edges, screws, pedestals/legs. 

TO ORDER 

Call 1-800-FORMICA

 or visit here: 

https://www.formica.com/en-

us/campaigns/intentek/intentek-inquiry-form 

GENERAL SAFETY 

Please read this Technical Guide, Use & Care, Warranty, and 
Installation Guide and all warnings contained herein prior to handling 
the Intentek

 System. 

CUSTOMER SAFETY 

1.  For indoor use only.
2.  Do not overload electrical outlets.
3.  AC Adapter must be plugged into a compatible mains supply to 
 operate.
4. Intentek

 Electronics AC Adapter or equivalent must be used. 

5.  Never use the AC Adapter if damaged in any way.

6.  When using the AC Adapter or extension cord, confirm safety

 

 

precautions have been made so there are no tripping hazards.

7.  Keep any wiring used to connect Electronics Modules covered.

CUSTOMER USE & CARE AFTER INSTALLATION 

1.  Do not unscrew the electronics module housing without 
 

professional support. If internal parts are ever exposed, avoid 

 

contact with sharp objects and moisture.

2.  May not be housed outside of recommended temperature range.
3.  May not be stored outdoors.
4.  At all times, keep electronics module and AC adapter away from 

 

liquids.

5.  Do not place foreign or sharp objects in the electronics module 
 

or or blower inlet/outlet.

6.  Follow all cleaning instructions for decorative surface. Do not 
 

attempt to clean inside of electronics module.

OUTLET

INLET

Содержание Intentek

Страница 1: ...ons 7 Intentek Wireless Charging Surfaces May Be Applied To 7 Tools Materials Sold by Formica Group 8 Additional Tools Materials Needed 8 Approved Adhesives 8 Important Installation Tips Reminders 9 B...

Страница 2: ...lectronics Module ELECTRONICS MODULE PARTS WHAT IS WIRELESS CHARGING Wireless charging also known as wireless power transfer provides the ability to charge a device without charging cables The Intente...

Страница 3: ...o electronics modules near each other a blower inlet must be at least 8 from another blower s outlet This rule is to be followed only if blower inlet and outlet are designed to be near each other If I...

Страница 4: ...nclude but are not limited to ceramic cooktop cleaners oven cleaners rust removers coffeepot cleaners drain cleaners lime scale removers toilet bowl cleaners metal cleaners tub and tile cleaners If in...

Страница 5: ...storage are 50 90 F 10 32 C and 30 65 humidity Keep materials free from moisture dust and impact The material should never be stored in contact with the floor or an outside wall Laminate sheets and b...

Страница 6: ...LD3 2005 Architectural Woodwork Quality Standards and ANSI A161 2 1998 Standards Fabricating with peel coat on surface is recommended Router base should be clean and free of burrs and debris All work...

Страница 7: ...CUT a Formica Group requires using a perimeter cut for the contact pad area MDF Particleboard Plywood will be removed after CNC cut is complete For this perimeter cut we recommend to use 1 4 or 3 8 b...

Страница 8: ...ecorative laminate sheet to the CNC alignment pins on the vacuum table prior to initiating the cutting operation 3D WARNING Machining must not contact the charging zone area contact pads which will im...

Страница 9: ...ot to pull off the gray gap pad 5C ALIGN HEAT SINK Align the heat sink in the cavity by visually centering the heat sink holes on all of the silver contact pads 5D PLACE 1ST SCREW IN HEAT SINK Press t...

Страница 10: ...e b Locate the parent electronics module the parent is the one that will be plugged into the AC Adapter c Using a wire stripper strip 3 16 off one end of the red and white wires to expose the wire und...

Страница 11: ...tem in opposite corners to use as guides to drop housing system in This will help protect pogo pins Remove alignment screws before proceeding to next step 5H ATTACH ELECTRONICS HOUSING Press and attac...

Страница 12: ...st procedure in Test Receiver manual If an electronics module is ever re installed it must be recalibrated for Foreign Object Detection Call 1 800 FORMICA or reference Test Receiver Manual for this pr...

Страница 13: ...Formica Group Technical Guide 13 FTB 0918 Rev 2 6 20 TECHINCAL GUIDE USE CARE WARRANTY AND INSTALLATON GUIDE INTENTEK WIRELESS CHARGING SURFACE PHYSICAL PROPERTIES OF INTENTEK LAMINATE BACKERS...

Страница 14: ...mica Group Technical Guide 14 FTB 0918 Rev 2 6 20 TECHINCAL GUIDE USE CARE WARRANTY AND INSTALLATON GUIDE INTENTEK WIRELESS CHARGING SURFACE ELECTRONIC MODULE AND AC ADAPTER SPECIFICATIONS AND COMPLIA...

Страница 15: ...en ETL Listed for testing to the UL2738 An ETL Listed mark will be found on the Electronics Module LEGAL TERMS AND CONDITIONS OF USE INTELLECTUAL PROPERTY AND CONFIDENTIALITY This Intentek Wireless Ch...

Страница 16: ...on of Intentek Wireless Charging Surface repaired or replaced under this limited warranty shall be at the Buyer s sole cost and expense which shall include the following costs the cost of dismantling...

Страница 17: ...ll and requesting a designated e waste drop off location TECHNICAL SERVICES Formica Corporation maintains a sales and technical services staff in Cincinnati Ohio For technical assistance contact your...

Отзывы: