Formica Intentek Скачать руководство пользователя страница 15

Formica Group Technical Guide

   |   15

FTB-0918  |  Rev 2  |  6/20

TECHINCAL GUIDE USE & CARE, WARRANTY, AND INSTALLATON GUIDE 

INTENTEK

™ 

WIRELESS CHARGING SURFACE 

LIFETIME EXPECTANCY TESTING

The electronic module has undergone accelerated life testing to 
simulate seven years of continuous use.  Lifetime Expectancy is not 

equivalent to warranty. See Warranty Section within this guide for 

additional details.

FCC COMPLIANCE STATEMENT

This device complies with Part 18 of the FCC Rules Warning:  

Changes or modifications to this unit not expressly approved by the 

party responsible for the compliance could void the user’s authority 

to operate the equipment. Note: This equipment has been tested 
and found to comply with the limits for ISM equipment, pursuant 

to Part 18 of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in a residential/

commercial installation. This equipment generates, uses, and can 
radiate radio frequency energy and, if not installed and used in 

accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that 

interference will not occur in a particular installation. If this equipment 

does cause harmful interference to radio or television reception, 

which can be determined by turning the equipment off and on, the 

user is encouraged to try to correct the interference by one or more 
of the following measures: 

•   Reorient or relocate the receiving antenna.

•   Increase the separation between the equipment and receiver.
•   Connect the equipment into an outlet on a circuit different from

 

 

that to which the receiver is connected.

•   Consult the dealer or and experienced radio/TV technician for 
 help.

The user is cautioned that changes and modifications made to the 
equipment without the approval of manufacturer could void the user’s 
authority to operate this equipment.
•   The operating Frequency band(s): 111.920kHz
•   “Hereby, Formica Group declares that the radio equipment type

 

 

Wireless Power Charge is in compliance with Directive 

 

2014/53/EU. The full text of the EU declaration of conformity 

 

is available at the following URL:  

 

https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32014L0053

•   No restriction for EU countries.

•   This equipment complies with radiation exposure limit set forth

 

 

for an uncontrolled environment. This equipment should be

 

 

installed and operated with minimum distance 20 cm between 

 

the radiator and your body.

UL STANDARDS

The AC adapter has been TUV Rheinland Listed for testing to the 
UL 60950-1. The TUV Listed mark will be on the AC adapter. The 
Electronics Module has been ETL Listed for testing to the UL2738.  
An ETL Listed mark will be found on the Electronics Module.

LEGAL TERMS AND CONDITIONS OF USE

INTELLECTUAL PROPERTY AND CONFIDENTIALITY

This Intentek

 Wireless Charging Surfaces Guide contains proprietary 

and confidential intellectual property owned by Formica Group. The 

information in this Guide is provided solely to assist in using the 
Intentek

 System and may not be disclosed or used for any other 

purpose.  

WARRANTY 

INTENTEK

™ 

WIRELESS CHARGING SURFACES 

LIMITED WARRANTY

1. Limited Warranty. 

The Intentek

 Wireless Charging Surface 

consists of Intentek

 laminate, laminate backer, electronics module 

and power cord. FORMICA warrants to the Buyer to which FORMICA 
has sold its Intentek

 Wireless Charging Surface (the “Buyer”), that 

for a period of (1) one year from the date of first sale, this product will 
be of merchantable quality, reasonably free of defects in materials 

and workmanship, manufactured in accordance with applicable 
Qi standards, and that when properly stored, handled, fabricated 
and installed, will conform, within accepted tolerance, to the 

specifications stated in the Material Properties Datasheet published 

on the date of delivery at www.Formica.com. Only the limited 
warranty published at www.Formica.com as of the date of initial 
shipment of the Intentek

 Wireless Charging Surface to the Buyer 

shall be applicable and effective. 

2. Remedy.

 In the event that an Intentek

 Wireless Charging 

Surface fails to conform to this limited warranty, FORMICA shall, at 
its sole option and discretion, either repair the defective Intentek

 

Wireless Charging Surface  or furnish replacement Intentek

 Wireless 

Charging Surface. The period of limited warranty applicable to a 
repaired or replaced Intentek

 Wireless Charging Surface shall 

be the remainder of the unexpired period of this limited warranty.  
If FORMICA chooses to repair the defective Intentek

 Wireless 

Charging Surface, FORMICA or its agent must be allowed to make 
the repair. If FORMICA chooses to supply new Intentek

 Wireless 

Charging Surface, FORMICA is only obliged to supply Intentek

 

Wireless Charging Surface that matches the color of the product 
originally supplied as closely as possible and is not obliged to supply 
an identical color.  

3. Limited Warranty Conditions. 

This limited warranty shall be null 

and void and/or shall be deemed revoked upon any failure to fully 
adhere to any of the following conditions:

 

1. the Buyer has paid the price of the Intentek

 Wireless 

 

Charging Surface  in full and has complied with all its 

 

(payment) obligations to FORMICA;

 

2. the Intentek

 Wireless Charging Surface  shall have 

 

been installed to meet all applicable codes and standards, 

 

laws and regulations;

 

3. the storage, transport, processing, application, 

 

fabrication, installation and/or maintenance instructions for 

Содержание Intentek

Страница 1: ...ons 7 Intentek Wireless Charging Surfaces May Be Applied To 7 Tools Materials Sold by Formica Group 8 Additional Tools Materials Needed 8 Approved Adhesives 8 Important Installation Tips Reminders 9 B...

Страница 2: ...lectronics Module ELECTRONICS MODULE PARTS WHAT IS WIRELESS CHARGING Wireless charging also known as wireless power transfer provides the ability to charge a device without charging cables The Intente...

Страница 3: ...o electronics modules near each other a blower inlet must be at least 8 from another blower s outlet This rule is to be followed only if blower inlet and outlet are designed to be near each other If I...

Страница 4: ...nclude but are not limited to ceramic cooktop cleaners oven cleaners rust removers coffeepot cleaners drain cleaners lime scale removers toilet bowl cleaners metal cleaners tub and tile cleaners If in...

Страница 5: ...storage are 50 90 F 10 32 C and 30 65 humidity Keep materials free from moisture dust and impact The material should never be stored in contact with the floor or an outside wall Laminate sheets and b...

Страница 6: ...LD3 2005 Architectural Woodwork Quality Standards and ANSI A161 2 1998 Standards Fabricating with peel coat on surface is recommended Router base should be clean and free of burrs and debris All work...

Страница 7: ...CUT a Formica Group requires using a perimeter cut for the contact pad area MDF Particleboard Plywood will be removed after CNC cut is complete For this perimeter cut we recommend to use 1 4 or 3 8 b...

Страница 8: ...ecorative laminate sheet to the CNC alignment pins on the vacuum table prior to initiating the cutting operation 3D WARNING Machining must not contact the charging zone area contact pads which will im...

Страница 9: ...ot to pull off the gray gap pad 5C ALIGN HEAT SINK Align the heat sink in the cavity by visually centering the heat sink holes on all of the silver contact pads 5D PLACE 1ST SCREW IN HEAT SINK Press t...

Страница 10: ...e b Locate the parent electronics module the parent is the one that will be plugged into the AC Adapter c Using a wire stripper strip 3 16 off one end of the red and white wires to expose the wire und...

Страница 11: ...tem in opposite corners to use as guides to drop housing system in This will help protect pogo pins Remove alignment screws before proceeding to next step 5H ATTACH ELECTRONICS HOUSING Press and attac...

Страница 12: ...st procedure in Test Receiver manual If an electronics module is ever re installed it must be recalibrated for Foreign Object Detection Call 1 800 FORMICA or reference Test Receiver Manual for this pr...

Страница 13: ...Formica Group Technical Guide 13 FTB 0918 Rev 2 6 20 TECHINCAL GUIDE USE CARE WARRANTY AND INSTALLATON GUIDE INTENTEK WIRELESS CHARGING SURFACE PHYSICAL PROPERTIES OF INTENTEK LAMINATE BACKERS...

Страница 14: ...mica Group Technical Guide 14 FTB 0918 Rev 2 6 20 TECHINCAL GUIDE USE CARE WARRANTY AND INSTALLATON GUIDE INTENTEK WIRELESS CHARGING SURFACE ELECTRONIC MODULE AND AC ADAPTER SPECIFICATIONS AND COMPLIA...

Страница 15: ...en ETL Listed for testing to the UL2738 An ETL Listed mark will be found on the Electronics Module LEGAL TERMS AND CONDITIONS OF USE INTELLECTUAL PROPERTY AND CONFIDENTIALITY This Intentek Wireless Ch...

Страница 16: ...on of Intentek Wireless Charging Surface repaired or replaced under this limited warranty shall be at the Buyer s sole cost and expense which shall include the following costs the cost of dismantling...

Страница 17: ...ll and requesting a designated e waste drop off location TECHNICAL SERVICES Formica Corporation maintains a sales and technical services staff in Cincinnati Ohio For technical assistance contact your...

Отзывы: