35-2. Connecting Control Panels
Up to three control panel units (HVS-392OU / HVS-392ROU / HVS-392WOU / HVS-391OU can
be connected to the HVS-390HS via Arcnet. The HVS-390HS stores three sets of panel settings,
which allow you to control the MU in the same way or differently from the control panels.
IMPORTANT
To change the Arcnet ID of a control panel, connect the control panel and HVS-390HS
one to one
. The Arcnet
ID
numbers and
OU NO
must be unique. Do not assign the
same ID number to two different devices. See section 3-3. "How to Connect between
MU and OU Units."
Each control panel can use different assignments for bus buttons and user buttons, and two
HVS-30OU units can control the MU differently, one for M/E1 and the other for M/E2, as shown
below.
To set up the above configuration, proceed as follows:
(1) Connect the first HVS-30OU and set the ARCNET menu as shown below:
SYSTEM : OU ID : OU NO :CTRL MU: GROUP : 1/2
ARCNET : =
2
: =
OU2
: =250 : =
390HS
:
(2) Connect the second HVS-30OU and set the ARCNET menu as shown below:
SYSTEM : OU ID : OU NO :CTRL MU: GROUP : 1/2
ARCNET : =
3
: =
OU3
: =250 : =
390HS
:
(3) Set the [SETUP - INPUT - ASSIGN] menu for the second HVS-30OU as shown below:
INPUT :SELECT : SHIFT : LINK :CONTROL: 6/6
ASSIGN : =
OU
: =OFF : =OFF : =
M/E2
:
(4) Connect the HVS-390HS and all control panels. Each control panel uses a different set of
settings in its assignments to control the MU.
EDITOR
OPTION SLOT
AC100-240V 50/60Hz IN
2
RS-422
AUX
HDMI
GPI IN
SDI OUTPUT
1
2
A
B
1
2
1
2
1
2
1
2
3
4
5
6
7
8
SDI INPUT
9
10
11
12
13
1 4
1 6
15
GPI/TALLY OUT
OPTION SLOT
C
D
1
AC100-240V 50/60Hz IN
RATING LABEL
TO OU
GENLOCK
REF IN
REF OUT
L AN
1
2
3
4
5
6
75
Ω
termination
Arcnet
HVS-392OU
OU ID=
1
(default)
OU NO =
OU1
(default)
HVS-30OU (First)
OU ID=
2
OU NO =
OU2
GROUP=
390HS
CONTROL = M/E1
HVS-30OU (Second)
OU ID=
3
OU NO =
OU3
GROUP=
390HS
CONTROL = M/E2
HVS-390HS
Arcnet ID=
250
(default)