![FOR-A HVS-390HS Скачать руководство пользователя страница 140](http://html1.mh-extra.com/html/for-a/hvs-390hs/hvs-390hs_operation-manual_2316756140.webp)
140
Detailed Data Selection for Saving Events
Data saved to the event can be selected under the [EVENT MEMORY] menu or [EVENT
STORE] menu as shown below.
[EVENT MEMORY] menu
Item
Setting
Description
*RATE
OFF, 1 to 999
See section 16-2-3. "Transitions Using Event Recall."
AUX BUS
ON, OFF
Setting to ON stores all AUX bus data. To set the AUX
bus data individually, set in the [EVENT STORE] menu.
*KEY ASG
ON, OFF
Setting to ON stores the output bus where KEY3 and
KEY4 images appear. (See section 10-9. Where KEY3
and KEY4 Appear.")
*SEQ RCL
ON, OFF
Setting to ON stores the current sequence data.
M/E BUS
ALL, M/E1, M/E2
Selects an M/E (or ALL) whose data is to be stored.
*CG WIPE
ON, OFF
Setting to ON stores the current CG WIPE data.
* Indicates the same item in both [EVENT MEMORY] and [EVENT STORE] menus.
EVENT : PAGE :DIRECT :PAGECLR: RATE : 1/3
MEMORY : =0 : =OFF : =CRNT : =OFF : L=0
EVENT :AUX BUS:KEY ASG:SEQ RCL:M/E BUS: 2/3
MEMORY : =OFF : =OFF : =OFF : =ALL : L=0
EVENT :CG WIPE: : 3/3
MEMORY : =OFF : : L=0
[EVENT STORE] menu
Item
Setting
Description
SELECT ALL
ME1BG,
ME1K1 to ME1K4
ME2BG
ME2K1 to ME2K4
Select ALL or a bus under
SELECT
.
Setting
DATA
to ON stores all data for the bus (including
signal selection, transition rate, transition type settings,
etc.).
Setting
XPT
to ON stores only the signal selection data.
Normally set to ON for
XPT
and
DATA
, so that
information for all buses is saved to events.
Set
DATA
to OFF if any data for the bus is not needed.
The data can be further selected when recalling events.
XPT ON,
OFF
DATA ON,
OFF
*RATE
OFF, 1 to 999
See section 16-2-3. "Transitions Using Event Recall."
AUX SEL
AUX1 to AUX8
Select an AUX bus at
AUX SEL
.
Setting
AUX RCL
to ON stores the information for the
bus.
AUX RCL
ON, OFF
*KEY ASG
ON, OFF
Setting to ON stores the output bus where KEY3 and
KEY4 images appear. (See section 10-9. Where KEY3
and KEY4 Appear.")
*SEQ RCL
ON, OFF
Setting to ON stores the current sequence data.
*CG WIPE
ON, OFF
Setting to ON stores the current CG WIPE data.
* Indicates the same item in both [EVENT MEMORY] and [EVENT STORE] menus.
EVENT :SELECT :XPT :DATA : RATE : 1/3
STORE : =ALL : =ON : =ON : =OFF :P.00