4
SETUP-OUTPUT menu
Sub menu
Parameter line
Parameter
(Turn F1 to move between.)
(Turn F2)
(Turn F3)
(Turn F4)
(Turn F5)
OUT CLEAN
DVE
KEY
SAFETY PGM
ENABLE
TYPE
CROSS
SAFETY PRV
ENABLE
TYPE
CROSS
SAFETY AUX1
ENABLE
TYPE
CROSS
SAFETY AUX2
ENABLE
TYPE
CROSS
SAFETY AUX3
ENABLE
TYPE
CROSS
SAFETY AUX4
ENABLE
TYPE
CROSS
SIDE PGM
ENABLE
TYPE
TRANSP
SIDE PREV
ENABLE
TYPE
TRANSP
SIDE AUX1
ENABLE
TYPE
TRANSP
SIDE AUX2
ENABLE
TYPE
TRANSP
SIDE AUX3
ENABLE
TYPE
TRANSP
SIDE AUX4
ENABLE
TYPE
TRANSP
ANCI BUS SEL
PGM SEL
PREV SEL
XPT LV
OUTPUT
ANCI OUT EN
AUX1
AUX2
AUX3
AUX4
Parameter
Default
Setting Range
Reference
CLEAN OFF
OFF, ON
DVE KEY
PGM
PGM, PST, ME A, ME B, KEY1, KEY2,
D KEY1, D KEY2, D KEY3, D KEY4,
ME KEY
6-1-2
ENABLE OFF
ON, OFF
TYPE OFF
OFF, 90K, 85K, 80K, 90B, 85B, 80B,
85B+80K, 90B+85K, 90B+80K, 85B+80B,
90B+85B, 90B+80B
CROSS OFF
ON, OFF
ENABLE
HD
OFF ON,
OFF
TYPE
HD
LINE LINE,
TRANSP
TRANSP
TYPE=
TRANSP
50 0-100
18-2-2
PGM SEL
OFF
OFF, AUX1-AUX4, EFF BG
PREV SEL
OFF
OFF, AUX1-AUX4, EFF BG
XPT LV
0
0~100
AUX1 - AUX4
OFF
ON, OFF
18-2-4
SETUP-DVE SETUP menu
Sub menu
Parameter line
Parameter
(Turn F1 to move between.)
(Turn F2)
(Turn F3)
(Turn F4)
(Turn F5)
P PAT CROP
T+B
R+L
ALL
SET
DVE SET
DVE MODE
KF DIR
EDGE
ROT STEP
FILTER
Parameter
Default
Setting Range
Reference
T+B 0
0 to 100.0
R+L 0
0 to 100.0
ALL 0
0 to 100.0
SET ---
9-4-4
KF DIR
NORMAL
NORMAL, REVERS
TRANS EDGE
OFF
OFF, ON
7-3-4
ROT STEP
1000
360, 1000, 4000
9-4-1
FILTER MODE1
MODE1, MODE2
7-3-4