138
18-5. Reboot and Initialization
18-5-1. Initializing the System
Press STATUS(SETUP) button with the SHIFT lit in the menu select section to open the
SYSTEM top menu.
Turn F1 to select SYSTEM and press F1 or the DOWN button to open the
SETUP-SYSTEM menu shown below.
Turn F1 to select the INIT line. In the INIT line, turn F2 to select which types of
initialization you want such as CUR, SYS and ALL. Then Press and hold down F2 at least
1 sec to initialize data. A "beep" sound will be heard when the data is initialized.
Setting
Description
CUR
All parameter data for MATT, PATTERN SELECT, KEY1, KEY2 and DSK
menus will be reinitialized. Related data can be saved to event memory.
SYS
Reinitialize only SYSTEM data settings. Related data cannot be event
memory saved.
ALL
Reinitialize all system setup data
18-5-2. Initializing OU Mode MENU
Only OU related data in the SETUP-OU MODE menu can be reinitialized using the OU INIT.
Press STATUS(SETUP) button with the SHIFT lit in the menu select section to open the
SYSTEM top menu.
Turn F1 to select OU MODE and press F1 or the DOWN button to open the SETUP-OU
MODE menu shown below.
Turn F1 to select the UTILITY line. In the UTILITY line, turn F5 to set to ON. Then press
and hold down F5 at least 1 sec to initialize data. A "beep" sound will be heard when the
data is initialized.
18-5-3. System Reboot
Press STATUS(SETUP) button with the SHIFT lit in the menu select section to open the
SYSTEM top menu.
Turn F5 to set REBOOT to ON. Then press and hold down F5 at least 1 sec to initialize
data. A "beep" sound will be heard when the MU is initialized.
IMPORTANT
Items requiring re-start display REBOOT MU on the menu screen are as follow:
All settings in the SETUP - MU MODE menu
ARCNET ID setting in the SETUP-NETWORK menu
IP ADDRESS and NETMASK settings in the SETUP-NETWORK menu