AST 14 C 255/00
opening time
P75
Rise in nominal boiler temperature with
zone board
0 ÷ 35 °C
5 °C
Useful to balance thermal
shocks at the circuit
breaker
P76
Thermal discharge enabling with solar card
0 ÷ 1
0
0 = disabled
1 = enabled
P78
Interface back-lighting switching on
0 ÷ 2
0
0 = standard (off)
1 = LCD always on
2 = LCD + keys always on
System check
P80
Multifunction relay forcing
0 ÷ 1
0
0 = standard function
1 = relay energised
P81
Zone 2 pump relay forcing
0 ÷ 1
0
0 = standard function
1 = relay energised
P82
Zone 2 mixing valve forcing
0 ÷ 2
0
0 = standard function
1 = force opening
2 = force closing
P84
Zone 3 pump relay forcing
0 ÷ 1
0
0 = standard function
1 = relay energised
P85
Zone 3 mixing valve forcing
0 ÷ 2
0
0 = standard function
1 = force opening
2 = force closing
P87
Zone 4 pump relay forcing
0 ÷ 1
0
0 = standard function
1 = relay energised
P88
Zone 4 mixing valve forcing
0 ÷ 2
0
0 = standard function
1 = force opening
2 = force closing
P90
Solar card pump relay forcing
0 ÷ 1
0
0 = standard function
1 = relay energised
P91
Solar card valve relay forcing -
opening
0 ÷ 1
0
0 = standard function
1 = relay energised
P92
Solar card valve relay forcing - closing
0 ÷ 1
0
0 = standard function
1 = relay energised
P93
DHW 3-star function with connected remote
control
(currently unavailable)
0 ÷ 1
0
0 = OFF
1 = ON
P94
Automatic filling enabled
0 ÷ 1
1
0 = disabled
1 = enabled
P95
Maximum current to modulation coil
(point C of curve)
0 to 170 mA
According
to P0
See modulation diagram
on page 42
P96
Minimum current to modulation coil
(point B of curve)
0 to 170 mA
According
to P0