36
8. TECHNICAL SPECIFICATIONS TABLES - GAZELLE EVO
MODEL
3000
5000
7000
G20
G31
G20
G31
G20
G31
Type
C13, C53
C13, C53
C13, C53
Categor
y
II2H3P
II2H3P
II2H3P
Nominal heat input (Qn)
kW
2.90
4.90
6.40
Reduced heat input (Qr)
kW
2.00
3.00
4.50
Nominal heat output (Pn)
kW
2.72
4.52
5.88
Reduced heat output (Pr)
kW
1.89
2.85
4.23
Efficiency at nominal heat output
%
93.7
93.5
92.2
92.3
91.8
91.7
Efficiency at reduced heat output
%
94.5
94.7
94.9
95.1
94.0
93.8
NO
X
emissions at Qn (on Hs)
mg/kWh
55
73
74
89
95
121
NO
x
emission class
-
5
5
5
5
5
5
Straight flue gas duct outer diameter
mm
55
55
55
Split pipe outer diameter
mm
Ø 35 and Ø 60
Ø 35 and Ø 60
Ø 35 and Ø 60
Power absorption
W
24
24
30
Voltage and frequency
V - Hz
230 - 50
230 - 50
230 - 50
Protection degree
IP
20
20
20
Tab.6
GAZELLE EVO 3000
G20
G31
Main burner nozzle
mm/100
245
200
Supply pressure
mbar
20
37
Offset value for gas valve
Pa
-0.5 ± 5
-1.1 ± 5
ΔP
Pa
180 ÷ 220
180 ÷ 220
Standard consumption
-
0.31 m
3
/h
0.23 kg/h
CO
2
(Qn)
%
9.5 ± 0.3
10.6 ± 0.3
CO
2
(Qr)
%
9.0 ± 0.3
10.4 ± 0.3
Tab.7
GAZELLE EVO 5000
G20
G31
Main burner nozzle
mm/100
365
290
Supply pressure
mbar
20
37
Offset value for gas valve
Pa
1.0 ± 5
-2.3 ± 5
ΔP
Pa
120 ÷ 150
120 ÷ 150
Standard consumption
-
0.52 m
3
/h
0.38 kg/h
CO
2
(Qn)
%
9.3 ± 0.3
10.6 ± 0.3
CO
2
(Qr)
%
9.0 ± 0.3
10.3 ± 0.3
Tab.8
GAZELLE EVO 7000
G20
G31
Main burner nozzle
mm/100
480
350
Supply pressure
mbar
20
37
Offset value for gas valve
Pa
-2.8 ± 5
-2.3 ± 5
ΔP
Pa
90 ÷ 110
90 ÷ 110
Standard consumption
-
0.68 m
3
/h
0.50 kg/h
CO
2
(Qn)
%
9.3 ± 0.3
10.4 ± 0.3
CO
2
(Qr)
%
9.0 ± 0.3
10.0 ± 0.3
Tab.9