4.2.4 Intake and vent pipe length
The maximum allowed length of pipes depends on the flow resistance of each part installed to go from the equipment up to the intake
and vent points.
Overall flow resistance, calculated according to tables 4 and 5, must not exceed the “Maximum allowed length”. The calculation must
consider both vent and intake ducts and should change based on the diameter of the pipes used (35 mm or 60 mm).
Gazelle EVO
Type
m.u.
3000
5000
7000
Maximum allowed length (*)
C13
m
2 (**)
2 (**)
2 (**)
C53 - Ø 35 mm
m
13
7
6
C53 - Ø 35 mm + Ø 60 mm
m
100
100
70
Tab.3
(*) vent
(**) Using the pipes supplied by the manufacturer: one for air and the other for flue gas, each shaped to be equivalent to a semicircle
diameter 55 mm. 1 meter long pipes are available as accessories.
WARNING
If using ONLY pipes diameter 35 mm, use flow resistance values from table 4.
If using pipes diameter 35 and 60 mm, use flow resistance values from table 5.