7. TROUBLESHOOTING
WARNING
The user must strictly comply with the relevant instructions ONLY aimed to users.
The user MUST NOT follow the instructions that are specific for qualified staff or personnel.
Malfunction
For the user
Only for qualified staff
Probable cause
Possible remedies
The burner does not
ignite and equipment
shuts down.
Fault code
E01
shown
on display.
Check that the gas tap is
open and light a kitchen
gas ring for example to
check the gas supply.
Press key
.
If equipment does not
restart after five reset
attempts, contact an
Authorised Service Centre
or qualified personnel and
specify the fault code.
No gas supplied
Make sure the gas tap is open.
Check that gas supply reaches the
valve.
Air inside the piping
Repeat the ignition sequence a few
times
There is no spark
Check the ignition transformer
Check the ignition electrode
The gas nozzle is dirty
Wash and blow it
The electronic safety board is not
working
Replace it
The main burner
does ignite but
immediately turns off
and equipment shuts
down.
Fault code
E01
shown
on display.
Flame detection cable is
disconnected
Re-connect it
Detection electrode is grounded
Replace it
Too much air at the burner
Carefully bleed the gas system (for
Propane gas)
Wrong calibration setting of the
burner
Calibrate the burner
Equipment is off,
display shows
E02
Check that the air outlet
grilles on the casing are
not obstructed and there
are no curtains hindering
air circulation.
Allow equipment to cool
down before restarting it.
If equipment shuts
down again, contact an
Authorised Service Centre
or qualified personnel and
specify the fault code.
The air safety thermostat was
triggered due to overtemperature
Check equipment operation
The air safety thermostat is faulty.
Replace it
The heat exchanger safety
thermostat was triggered due to
overtemperature
Check equipment operation and
current gas settings
The heat exchanger safety
thermostat is faulty
Replace it
Tangential fan is not working
Replace it
The electronic safety board does not
supply the tangential fan
Replace it
Equipment is off,
display shows
E03
Check that intake and vent
terminals are not clogged
with objects, leaves,
snow, ice or any other
obstruction.
Remove obstruction, if
any; equipment will restart
autonomously.
If intake and vent terminal
is not obstructed, contact
an Authorised Service
Centre or qualified
personnel and specify the
fault code
The air pressure switch does not
trigger
Check that intake and vent pipes
are not clogged, squashed or
disconnected.
Air pressure switch is faulty
Replace it
Combustion fan is blocked or not
efficient
Replace it
There are obstructions in the air
intake and/or flue gas venting pipes
Remove any obstructions
The electronic safety board does not
supply power to the centrifugal fan
Replace it