- CHANNEL 2
As described in the “thermal unit managing one high temperature
CH area and DHW supply” section.
The programmer can host up to 8 ON daily times and 8 OFF daily
times. 5 programmable time areas are available for each day, for
repetition of ON/OFF programs within the same week (1: single
day; 2: Mon-Fri; 3: Sat-Sun; 4: Non-Sat; 5: Mon-Sun).
“Comfort” position.
Boiler CH operation management only. Programmer is considered
as always turned ON, regardless of its programs. Room tempera-
ture is the one set as “COMFORT”.
Room thermostats turn ON or OFF the relevant zone pumps, and
when all room thermostats are set to OFF, CH demands termina-
te.
“Reduced” position
Boiler CH operation management only. Programmer is considered
as always turned OFF, regardless of its programs. Room tempera-
ture is the one set as “REDUCED”.
Room thermostats turn ON or OFF the relevant zone pumps, and
when all room thermostats are set to OFF, CH demands termina-
te.
Knob 13
is disabled for CH flow temperature adjusting, it sets the
fictitious room temperature (please, see “SLIDING” TEMPERATU
-
RE OPERATION section).
“SLIDING” TEMPERATURE
The boiler adjusts the temperature of CH flow to the high tempera
-
ture zone (temperature of the radiators) and the temperature of the
low temperature zone (floor heating) following the signals from:
- external temperature readings from the external probe
- desired room temperature to be set through knob 13. 12°C to
28°C range.
Knob 13 turned fully counter-clockwise correspond to 12°C room
temperature; knob 13 set to 09:00 hours correspond to 15°C; knob
13 set to 12:00 hours correspond to
20°C; knob 13 set to 03:00 hours cor-
respond to 25°C; knob 13 turned ful-
ly clockwise correspond to 28°C; for
best CH curve setup, turn knob 13 to
position corresponding to 20°C;
1.2.2.5 Anti-Legionella function
Anti-Legionella function is activated
every 15 days, it consists in heating
up the water tank to 65°C for 30 mins,
regardless of all other setups.
1.2.2.6 Pump anti-seizure function
When the pumps or electric valves are left inactive for 24 hours,
the pump anti-seizure function operates the pumps and electric
valves for 3 mins.
1.2.2.7 Phone operation function
When a phone operation module is connected to the boiler pcb, the
“COMFORT” function and the loading of the boiler can be remotely
activated regardless of knob 11 position.
1.2.3 Electronic programmer setup
A. Initialization
When setting up the programmer for the first time or re-program
-
ming it, it is advisable to reset it by turning selector 2 to RUN and
pressing the reset micro-switch R: Time, ON and OFF programs
will be deleted (time display will flash 0:00).
In order to set the day of the week, current time, ON and OFF pro-
grams, please see below sections B and C.
B. Setting the day of the week and current time
Position selector 2 to RUN and press h and m buttons at the same
time, until the two dots dividing hours and minutes display stop
flashing (If the reset micro-switch
R was previously pressed, the
time display stops flashing also); press button
1...7 in order to set
the day of current week (displayed by indicator 8), press button h
in order to set current hour, press button m in order to set current
minutes (when h and m are simultaneously pressed, the digital
display runs fast).
Wait for approximately ten seconds until the two dots dividing hours
and minutes display start flashing. Now the day of the week and
current time setup procedure is completed.
C. ON and OFF program setup
Set selector 2 to P1 in order to program channel 1 and to P2 in
order to program channel 2 (display 3 indicates the number of cho-
sen channel, indication 4 displays
symbol to indicate that we
are setting an ON time, display 5 indicates 1
as the first program is
being set; up to 8 ON and OFF intervals are available for program-
ming, that is 16 times).
Follow the below described procedure in order to set the ON time:
- press button 1...7 in order to set the desired of the week (or days
of the week
(1)
);
- press button h and then button m in order to set hour and minutes
of the ON time;
- press button
in order to confirm the programmed ON time and
proceed to the programming of the OFF time (indicator 4 is off and
it indicates that an OFF time is being set; indicator 5 displays 2
indicating the second time is being set).
Follow again the above described procedure, in order to set the
OFF program and after that, press
button.
Now one boiler operation interval is set through its ON and OFF
programmed times, indicator 5 displays 3; In order to set an addi-
tional ON time, follow the above instructions, or move selector 2 to
RUN in order to terminate the programming procedure.
(1)
By repeatedly pressing button 1...7, the following programmable
time areas are available in order to automatically repeat the ON
and OFF programs within the same week:
No. 1 programmable time area: single week day
No. 2 programmable time area: Monday through Friday
No. 3 programmable time area: Saturday and Sunday
No. 4 programmable time area: Monday through Saturday
No. 5 programmable time area: Monday through Sunday
When programming an ON time in a multi-day programmable time
area (e.g. no. 2), the OFF time must be set in the same program-
mable time area in order to make it effective to all days included in
the area.