This  INSTRUCTION  MANUAL, 
which  is  an  integral  and  indispen-
sable  part  of  the  product,  must  be 
delivered to the user by the installer 
and must be kept in a safe place for 
future  reference.  The  manual  must 
accompany  the  boiler  should  it  be 
sold or its possession transferred. 

The  boiler  must  be  used  for  the 
purposes  for  which  it  has  been 
intended. Any other use shall be 
considered  incorrect  and  there-
fore dangerous. 

The boiler must be installed in com-
pliance  with  applicable  laws  and 
standards  and  according  to  the 
manufacturer’s instructions given in 
this  manual.  Incorrect  installation 
may cause injury to persons and/or 
animals  and  damage  to  property. 
The manufacturer shall not be held 
liable  for  any  such  injury  and/or 
damage. 

Damage  and/or  injury  caused  by 
incorrect  installation  or  use  and/or 
damage  and/or  injury  due  to  non-
observance  of  the  manufacturer’s 
instructions  shall  relieve  the  manu-
facturer from any and all contractual 
and/or extra-contractual liability. 

Before  installing  the  boiler,  check 
the technical data to be compatible 
with the requirements for its opera-
tion in the system.

Check that the boiler is intact and it 
has not been damaged during tran-
sport  and  handling.  Do  not  install 
equipment  which  is  damaged  and/
or faulty.

Do not obstruct the air suction and/
or heat dissipation openings. 

Only manufacturer-approved acces-
sories  and  optional  kits  are  to  be 
installed.

Properly  dispose  of  the  packaging 
as all the materials can be recycled. 
The  packaging  must  therefore  be 
sent to specific waste management 
sites. 

Keep the packaging out of the reach 
of  children  as  by  its  nature  it  may 
represent a hazard.

In  the  event  of  failure  and/or  faulty 
functioning, switch off the boiler. Do 
not attempt to repair it and contact a 
qualified service technician. 

Manufacturer-approved  parts  must 
be used for all repairs to the boiler. 

Non-observance of the above requi-
rements  may  affect  the  safety  of 
the  boiler  and  endanger  people, 
animals and property.

The  manufacturer  recommends 
our  Customers  to  have  the  boiler 
serviced  by  an  Authorized  Service 
Centre. 

In  order  to  guarantee  efficient 
and  correct  functioning  of  the 
equipment it is legally binding to 
have  the  boiler  serviced  once  a 
year,  according  to  the  schedule 
specified  in  the  relevant  section 
of this manual.

In the event of long periods of inac-
tivity of the boiler, disconnect it from 
power mains and close the gas tap 
(Warning:  the  boiler  anti-frost  func-
tion is disabled).

Should  there  be  a  risk  of  freezing, 
add  antifreeze:  it  is  not  advisable 
to  empty  the  system  as  this  may 
result in damage; use specific anti-
freezing products suitable for multi-
metal heating systems.

IMPORTANT

Should gas smell be perceived pro-
ceed as follows:

-  do  not  turn  on  or  off  electri-
cal  switches  and  do  not  turn  on 
electrical appliances;
- do not ignite flames and do not 
smoke;
- close the main gas tap;
- open doors and windows;
- contact a Service Centre, a qua-
lified  installer  or  the  gas  supply 
company.

Never  use  a  flame  to  detect  gas 
leaks.

        WARNING

This  boiler  has  been  built  for  installation  in  the  country  indicated  on 
the technical data plate: installation in any other country may be sour-
ce of danger for people, animals and property.

2

General information for the installer, maintenance technicians and users

Содержание BALI B BTFSE 24

Страница 1: ...IST 03 C 192 01 INSTALLATION USE AND MAINTENANCE BALI B BTNE 25 BTNE 32 BTNE 42 BTFSE 24 BTFSE 32 BTFSE 36 GB...

Страница 2: ...Dear Customer Thank you for choosing and buying one of our boilers Please read these instructions carefully in order to install operate and maintain this equipment properly 1...

Страница 3: ...ment sites Keep the packaging out of the reach of children as by its nature it may represent a hazard In the event of failure and or faulty functioning switch off the boiler Do not attempt to repair i...

Страница 4: ...of temperature probes page 9 1 3 Maintenance page 9 1 4 Information for the user page 9 2 Technical characteristics and dimensions page 10 2 1 Technical characteristics page 10 2 2 Dimensions page 10...

Страница 5: ...operates in CH and instantaneous DHW supply mode only As soon as the probe is replaced the boiler will resume operation 8 Indication light red when the light is on and fixed it indicates that the temp...

Страница 6: ...liters per minute relies upon the boiler thermal output and water main supply temperature according to the fol lowing formula l DHW in liters per minute K T K represents 344 for BTFS 24 model 459 for...

Страница 7: ...t when the boiler is equipped with an external temperature probe the user sets a fictitious room temperature va lue via knob 13 please see SLIDING TEMPERATURE OPERA TION section Knob 13 is used to adj...

Страница 8: ...of the week current time ON and OFF pro grams please see below sections B and C B Setting the day of the week and current time Position selector 2 to RUN and press h and m buttons at the same time unt...

Страница 9: ...will be displayed fixed and symbol will be displayed indicator 4 now the chan nel will be permanently active Rapidly set selector 1 to position O without stopping in position AUTO press once or twice...

Страница 10: ...usehold products Do not use water As provided by law the boiler is to be serviced once a year Correct maintenance ensures boiler to function efficiently environmentally friendly preventing any danger...

Страница 11: ...aracteristics High output cast iron heat exchanger Stainless steel plate DHW heat exchanger Stainless steel horizontal stratification 60 l water tank with sacrificial magnesium anode Glass wool alumin...

Страница 12: ...inlet C DHW flow F Cold water inlet M CH flow R CH return G Gas inlet C DHW flow F Cold water inlet M CH flow R CH return M1 Low temperature zone flow M2 Low temperature zone return D Flue gas outlet...

Страница 13: ...CAST HEAT EXCHANGER BURNER Plate heat exchanger probe Zone 1 high temperature Thermostatic valve DHW Cold water inlet Water tank probe Water tank VM 2 way Cold water inlet Zone 1 high temperature Zon...

Страница 14: ...16 4 Water tank capacity l 60 60 60 60 60 60 DHW supply T 30K EN 625 l 10 220 242 280 215 245 253 prEN 13203 efficiency rating Min DHW flow rate l min 3 3 3 3 3 3 Min DHW pressure bar 1 1 1 1 1 1 Max...

Страница 15: ...manual Four legs with threads 3 2 2 Choosing where to install the boiler When choosing where to install the boiler follow the instructions below indications in paragraph 3 2 5 Air flue gas system conf...

Страница 16: ...lination toward the ground of at least 5 The terminal is to ensure efficient constant evacuation of flue gas in any weather condition The flue gas terminal is to stand at least 0 5 m above any adjacen...

Страница 17: ...0 mm diameter split pipes Roof mounted flue gas terminal Allowable configuration for max length of split pipes 2 flanged stub pipes 1 meter long air intake pipe 30 meter long flue gas pipe 1 air intak...

Страница 18: ...damage or injury cau sed by failure to properly earth the power main Gas lines DHW and CH pipes are not suitable for earthing purpo ses 3 2 9 Hydraulic connections Before connecting the boiler it is a...

Страница 19: ...through water mains inlet tap on the boiler as necessary Water pressure adjustment must be performed when the system is cold The thermo manometer gauge on the boiler allows for che cking the pressure...

Страница 20: ...er P3 boiler operating mode selector P2 DHW temperature adjusting potentiometer P1 CH temperature adjusting potentiometer IG two poled main power switch BC flame detection pcb VG gas valve E RIV flame...

Страница 21: ...NECTION M1 M24 AVAILABLE CONNECTORS X1 X8 AVAILABLE CONNECTORS CT PHONE CONNECTION DEVICE OPTIONAL EQUIPMENT FUSE SP 2 AF 250 Vac FUSE FUSE SZ 2 5 AF 250 Vac FUSE P4 HIGH TEMPERATURE CH CURVES ADJUSTI...

Страница 22: ...ted by qualified personnel In order to verify nozzle and gas inlet pressure connect a mano meter to checks on the gas valve Boilers are factory set according to gas type requested upon order Any later...

Страница 23: ...the plate heat exchanger The boiler has shut down and red light no 4 is flashing Restore correct water pressure Insufficient water pressure Possible water leaks Check system for leaks Pressure switch...

Страница 24: ...has not sufficient pressu re or flow rate Check DHW system Check flow meter filter Flow meter sensor is faulty or discon nected Replace or reconnect it Flow meter is blocked Replace it Burner does not...