15
PeRfoRMAnCe AnD sPeCIfICAtIons
Line Inputs
All measurements taken at +24dBu reference level, Rs = 50Ω
0 dBFS Reference Level
+18 or +24dBu (switchable)
Frequency Response
20Hz – 20kHz ± 0.1dB
THD + N
<
-100dB (0.001%) unweighted, 20Hz – 20kHz; -1dBFS input
EIN
-96dBu ‘A’-Weighted (typical)
Signal-to-Noise Ratio
120dB ‘A’-Weighted (typical)
Converter Dynamic Range 120dB ‘A’-Weighted (typical), 10Hz – 20kHz
Line outputs
All measurements taken at +24dBu reference level, RL = 100kΩ
0 dBFS Reference Level
+18 or +24dBu (switchable)
Frequency Response
20Hz – 20kHz ± 0.1dB
THD + N
<
-100dB (0.001%) unweighted, 20Hz – 20kHz; +23dBu input
Noise in Presence of
Signal
-94dBu ‘A’-Weighted (typical)
Dynamic Range
118 dB ‘A’-Weighted (typical)
Convertor Dynamic Range 120dB ‘A’-Weighted (typical), 10Hz – 20kHz
Crosstalk
Input to Output or Input
<
-100dB unweighted, 20Hz – 20kHz; +23dBu input
Output to Input or Output
<
-100dB unweighted, 20Hz – 20kHz; -1dBFS input
Input sample Rate Converters
Sample Rate Range
32kHz to 216kHz
Gain Error
-0.3dB
Dynamic Range
>
138dB
THD+N
<
-130dB (0.00003%)
Latency
11 to 45 samples (network and sample rate dependent)