![Focusrite Rednet A16R Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/focusrite/rednet-a16r/rednet-a16r_user-manual_2314581013.webp)
13
ID (Identification)
Clicking on the ID icon
will identify the physical device being controlled by flashing its front panel
LEDs.
tools Menu
Clicking on the Tools icon
will gain access to the following system settings:
Line Level setup – Sets the analogue line output level at 0 dBFS:
• +18dBu
• +24dBu
Factory default setting
[Inputs 15 & 16 from xLR]
– Tick option
(RedNet A16R units only)
. When selected, analogue channels 15
and 16 are replaced by the AES/EBU channel pair.
Note: Option is only functional when unit is operating at quad sampling rate.
Preferred Master – On/Off state.
Rednet Clock source – Only one of the following can be selected at any time:
• Internal (RedNet is network master but running from internal clock)
• Work Clock Input - (BNC Input)
• XLR Input (DARS)
Note: When selecting any clock source, RedNet A8R/A16R will become a preferred master.
Word Clock Input termination – Tick option On/Off. (Terminates word clock input BNC with 75Ω.)
Word Clock output – One can be selected at any time.
• Network
• Network (Base Rate)
Aes/eBU Input sRC – On/Off state. Applicable to channels 9 & 10 [17 & 18]. Enables Sample Rate
Converters