Rear Panel Connectivity

Analogue Audio

Channel Count

8 [16] channels input and output

Input and Output

2 [4] x DB-25 female connectors (AES59 / Tascam Analogue)

Aes/eBU

Channel Count

2 channels input and output

Alternate Input (optional 

DARS)

1 x XLR-3 female [Switchable with analogue input channels 15 and 16 at quad rates]

Alternate Output

1 x XLR-3 male [Duplicate of analogue output channels 15 and 16 at quad rates]

Word Clock

Input

1 x BNC 75Ω port (switchable termination)

Output

1 x BNC 75Ω port

PsU & network

PSU

2 x IEC Inputs with retaining clips

Network

2 x etherCON NE8FBH, also compatible with standard RJ45 connectors

(Accomodates rugged etherCON NE8MC*. Does not intermate with Cat 6 cable connector 

NE8MC6-MO and NKE65* cable)

Digital Performance

Supported Sample Rates

44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz (-4% / -0.1% / +0.1% / +4.167%) at 24 bit

Clock Sources

Internal or from Dante Network Master.

External Word Clock 

Range

Nominal sample rate ±7.5%

front Panel Indicators

Primary PSU (A)

Green LED. Illuminates when an AC input is applied and all DC outputs are present. 

Primary PSU (B)

Green LED. Illuminates when an AC input is applied and all DC outputs are present. 

Primary Network

Green LED. Indicates that a network connection is present on primary port when in 

redundant mode. When in Switched mode, a valid network connection at either Primary or 

Secondary network port will cause this LED to illuminate. 

Secondary Network

Green LED. Indicates that a network connection is present on secondary port when in 

redundant mode. Not used in switched mode. 

Network Locked

Green LED. When unit is network slave, shows valid network lock. When unit is network 

master, shows lock to internal clock.

Sample Rate

Orange LED for each: 44.1 kHz, 48 kHz, x2, x4.

Pull Up/Down

Orange LED. Indicates that the unit is set to operate on a Dante pull up/down domain.

Channel Signal Level

8 [16] Input and 8 [16] Output tri-state signal level LEDs: Green LED (

>

 -42dB), Orange 

LED (

>

 -6dB) and Red (

>

 0dB)

AES/EBU

2 I/O signal indicator LEDs (one input, one output). Green LED illuminates 

>

-127dBFS

Clock Source

Orange LED for each: Internal, Word Clock and DARS

Содержание Rednet A16R

Страница 1: ...User Guide www focusrite com FFFA001382 03 ...

Страница 2: ...1 First Use and Firmware Updates 11 Digital Clocking 11 Pull Up and Pull Down Operation 11 Sample Rate Converters 11 OTHER REDNET SYSTEM COMPONENTS 12 USING REDNET CONTROL 12 Signal Metering 12 ID Identification 13 Tools Menu 13 Appendix 14 Connector Pinouts 14 Ethernet Connector 14 DB 25 AES59 Connector 14 XLR Connectors 14 Performance and specifications 15 Focusrite RedNet Warranty and Service 1...

Страница 3: ...ommend that all users including those already experienced in digital audio networking take the time to read through the System User Guide so that they are fully aware of all the possibilities that RedNet and its software have to offer Should either user guide not provide the information you need be sure to consult www focusrite com rednet which contains a comprehensive collection of common technic...

Страница 4: ... to an uninterruptible source Each PSU s status can be monitored remotely over the network or from the front panel RedNet A8R A16R has a Sample Rate Converter SRC on the AES EBU input pair allowing instant operation with any AES EBU source irrespective of the sample rate or clocking of the Dante network Audio interface is provided by two four standard 8 way AES59 DB 25 connections In addition chan...

Страница 5: ...hernet network Not used when operating in Switched mode LOCKED Illuminates when a valid sync signal is received from the network or when the RedNet A8R A16R unit is the Network Master Flashes if external clock is selected but not connected 4 RedNet Sample Rate Indicators Five orange indicators 44 1 kHz 48 kHz x2 multiple of 44 1 or 48 x4 multiple of 44 1 or 48 and sample rate PULL UP DOWN These In...

Страница 6: ...dBFS When a RedNet A16R unit is operating at quad sample rates the IN and OUT LEDs don t illuminate if Analogue mode has been selected 7 RedNet Clock Source Indicators Three orange indicators Internal Word Clock BNC input and DARS XLR input Whichever is lit identifies the clock reference being used When an incoming clock source is invalid the Locked indicator will flash to indicate that the unit h...

Страница 7: ... Network Port Secondary Dante network connection where two independent Ethernet links are being used Redundant mode or an additional port on an integral network switch on the primary network Switched mode 5 Word Clock Out Provides an output of the chosen system clock reference can be switched between base rate or network rate 6 Word Clock In Allows synchronisation of the Dante network to house wor...

Страница 8: ... outputs eight channels per connector Wired to the AES59 8 way standard also known as the Tascam standard Refer to the Appendix on page 14 for connector pinouts CET APPAREIL DOIT ETRE MIS A LA TERRE PAR LE CORDON D ALIMENTATION THIS EQUIPMENT MUST BE EARTHED BY THE POWER CORD ANALOGUE OUTPUTS OUT 1 8 OUT IN AC ONLY 100 240V 50 60 HZ 30VA PSU A PSU B PUSH PRIMARY SECONDARY PUSH Focusrite R WORD CLO...

Страница 9: ...t installed the retaining clips will need to be attached to the power input sockets on the rear panel Insert each clip by squeezing together the legs as shown in the first image below aligning the pins with the through holes on the IEC fixing posts one at a time and then releasing Ensure that the orientation of each clip is as shown in the other images below or the effectiveness will be compromise...

Страница 10: ... mount RedNet A8R A16R immediately above any other equipment which generates significant heat for example a power amplifier Also ensure that when mounted in a rack the side vents are not obstructed Power Requirements RedNet A8R A16R is mains powered It incorporates Universal power supplies which can operate on any AC mains voltage from 100 V to 240 V The AC connections are made via a standard 3 pi...

Страница 11: ...dNet Control We recommend keeping all RedNet units up to date with the latest firmware version supplied with each new version of RedNet Control Digital Clocking Each RedNet A8R A16R will automatically lock to a valid Network Master via its Dante connection Alternatively if a Network Master is not present then the unit can be chosen as the Network Master by the user Pull Up and Pull Down Operation ...

Страница 12: ...A8R with signals present on all input and output channels The unit has a single PSU input single network input and a locked network connection PSUs A B Each illuminates if PSU has power input and all DC outputs are present Networks Each illuminates if a valid connection is present Locked Unit is successfully locked to the network changes to the red cross if not locked Network Master Illuminated in...

Страница 13: ...channel pair Note Option is only functional when unit is operating at quad sampling rate Preferred Master On Off state RedNet Clock Source Only one of the following can be selected at any time Internal RedNet is network master but running from internal clock Work Clock Input BNC Input XLR Input DARS Note When selecting any clock source RedNet A8R A16R will become a preferred master Word Clock Inpu...

Страница 14: ...ut Connector type XLR 3 plug Applies to AES EBU Output Pin Cat 6 Core 1 White Orange 2 Orange 3 White Green 4 Blue 5 White Blue 6 Green 7 White Brown 8 Brown Pin Signal 1 Screen 2 Hot ve 3 Cold ve 1 1 8 1 8 1 13 25 14 Pin Signal 1 Channel 8 14 Channel 8 2 Ground 15 Channel 7 3 Channel 7 16 Ground 4 Channel 6 17 Channel 6 5 Ground 18 Channel 5 6 Channel 5 19 Ground 7 Channel 4 20 Channel 4 8 Ground...

Страница 15: ...ce level RL 100kΩ 0 dBFS Reference Level 18 or 24dBu switchable Frequency Response 20Hz 20kHz 0 1dB THD N 100dB 0 001 unweighted 20Hz 20kHz 23dBu input Noise in Presence of Signal 94dBu A Weighted typical Dynamic Range 118 dB A Weighted typical Convertor Dynamic Range 120dB A Weighted typical 10Hz 20kHz Crosstalk Input to Output or Input 100dB unweighted 20Hz 20kHz 23dBu input Output to Input or O...

Страница 16: ...el Indicators Primary PSU A Green LED Illuminates when an AC input is applied and all DC outputs are present Primary PSU B Green LED Illuminates when an AC input is applied and all DC outputs are present Primary Network Green LED Indicates that a network connection is present on primary port when in redundant mode When in Switched mode a valid network connection at either Primary or Secondary netw...

Страница 17: ...nt networks Switched Connects both ports to integrated network switch allowing daisy chaining of devices Power PSUs 2 x Internal 100 240V 50 60Hz consumption 24 41 W Dimensions Height 44 5mm 1 75 1RU Width 482 09mm 18 98 Depth 352 12mm 12 80 Weight Weight 4 52 4 78 kg ...

Страница 18: ...riate procedure for resolving the warranty issue In every case it will be necessary to provide a copy of the original invoice or store receipt to the distributor In the event that you are unable to provide proof of purchase directly then you should contact the reseller from whom you purchased the product and attempt to obtain proof of purchase from them Please do note that if you purchase a Focusr...

Отзывы: