3.2 Power
Power to the 914-HDE card is provided through connector J3, Molex P/N 09-75-2024. The mating plug is Molex
P/N 26-03-4020 with crimps P/N 08-52-0113. The pinout is provided in the table and figure below.
Figure 3-3: Power Input Connector Location
The recommended input voltage range is 4.5 VDC to 13.0 VDC (typ5 VDC regulated). Nominal power
consumption is 5 W, increasing to 5.5 W at 60
o
C ambient temperature. Power leads should be AWG 18
– 20.
The onboard surface mount fuse, F1, is rated to 2A and is not intended to be field replaceable. If the power
fuse is blown, the card should be evaluated for damage by the factory or trained service personnel prior to
any repair.
Pin #
Function
1
GND
2
VCC
Table 2: Power