Operating Manual DLS2
20
10
Technical Data
Parameter Value
Sensing width
8mm
Max. line width
5mm
Min. line width
0.5mm
Resolution 0.06mm
Measuring rate
2 ms
Output signal 0...10V
0…10V
Power supply
24VDC (18…30VDC)
Temperature range -10
…+50°C
Protection class
IP 54
11
Trouble Shooting
Error
Possible cause and solution
Wrong measuring results,
malfunction of the sensor
Electrostatic discharge of the web to the material
sensor can lead to malfunctions.
An additional electrostatic protection band can be
used as illustrated below.
FMS Force Measuring
Systems AG
Aspstrasse 6
8154 Oberglatt (Switzerland)
Tel. 0041 1 852 80 80
Fax 0041 1 850 60 06
[email protected]
www.fms-technology.com
FMS USA, Inc.
2155 Stonington Avenue
Suite 119
Hoffman Estates,, IL 60169
(USA)
Tel. +1 847 519 4400
Fax +1 847 519 4401
fmsusa@fms-
technology.com
FMS (UK)
Aspstrasse 6
8154 Oberglatt (Switzerland)
Tel. +44 (0)1767 221 303
FMS (Italy)
Aspstrasse 6
8154 Oberglatt (Switzerland)
Tel. +39 02 39487035