Operating Manual DLS2
7
Note
Regardless of the mounting side, the DLS2 line sensor must always be connected to the socket
for the RIGHT material sensor.
5.3
Wiring
Electrical connections:
If the sensor is used with a web guide
controller built-in in a FMS steering frame
of the webMASTER series, the sensor is
connected with a cable 4x0.14mm2 of
the respective length. We recommend
using FMS original cables. The cables can be
ordered at FMS.
Fig. 4
shows the sensor connector in
front view with its pin assignment. The
table lists the wire colour corresponding to
the signal names.
5.4
Using the DLS2 with FMS Web Guide Controllers
If using the DLS2 sensor with older web guide controllers of the types BKS110C and
BKS309, it may be necessary to adapt the driver strength of the 24 VDC supply of the
controller to the new sensor requirements. This is achieved by adding a wire bridge in
the 24V supply. The table below indicates in which cases this modification is necessary
and where the bridge has to be applied.
Used Controller in
Web Guide
Serial number on
Web Guide Frame
Wire bridge between
wire terminals
Remark
BKS309
Lower than 106745
4 and 13
BKS309 Higher than 106745
-
No wire bridge
BKS309
Firmware 2.43
Set operating
parameter
"DLS"
BKS110C.582339
All Web Guides
10 and 56
BKS110C
All Web Guides
20 and 56
Caution
If a Digital Line Sensor DLS2 is used in combination with older web guide
controllers of the types BKS110C and BKS309 V1.63 or older, a wire bridge needs to
be added in the 24 V controller supply. Consult the wiring diagram and wire terminal
arrangement in the operation manual of the respective controller to apply the bridge.
Fig. 4:
Pin assignment
DLS00008e