background image

Operating Manual DLS2 

 

 

1

 

Safety Instructions 

1.1

 

Description Conditions 

a) Danger of health injury or loss of life 

Danger 

This symbol refers to high risk for persons to get health injury or loss life. It has to be 
followed strictly. 

 

b) Risk of damage of machines 

Caution 

This symbol refers to information, that, if ignored, could cause heavy mechanical 
damage. This warning has to be followed absolutely. 

 

c) Note for proper function 

 

Note

 

This symbol refers to an important information about proper use. If not followed, 
malfunction can be the result. 

 

1.2

 

List of Safety Instructions 

If a Digital Line Sensor DLS2 is used in combination with older web guide 

controllers of the types BKS110C and BKS309 V1.63 or older, a wire bridge 
needs to be added in the 24 V controller supply. Consult the wiring diagram and 
wire terminal arrangement in the operation manual of the respective controller to 
apply the bridge. 

 

With

 special web guide controllers e.g. of the type BKS020.xxx.480.75.D.582339 

(ABG) the DLS2 sensor must be mounted on the right side of the steering frame. 

 

In web guiding systems all equipped with FMS components and a DLS2 sensor it 

may happen that the web guide controller blocks the steering frame. This 
protective function is activated when the line is interrupted and impossible to be 
detected. It avoids the steering frame from skittering away and material loses. 

 

In addition the DLS2 generates at permanent line interruption an alarm signal 
that can be used to shutdown the production line 

 

Содержание DLS2

Страница 1: ...nsor Document Version 1 10 03 2021 NS Firmware Version 1 3 Diese Bedienungsanleitung ist auch in Deutsch erh ltlich Bitte kontaktieren Sie Ihren n chstgelegenen FMS Vertreter by FMS Force Measuring Sy...

Страница 2: ...via the Front Panel 10 7 Commissioning of the DLS2 11 7 1 Initialisation Phase 11 7 2 Quick Installation Guide Initialisation Procedure 11 7 3 Horizontal Positioning 12 7 4 Adjustment of Focus 12 7 5...

Страница 3: ...e controllers of the types BKS110C and BKS309 V1 63 or older a wire bridge needs to be added in the 24 V controller supply Consult the wiring diagram and wire terminal arrangement in the operation man...

Страница 4: ...ns of powerful Digital Signal Processing algorithm The parameters for optimal contrast control mode line parameters etc will be stored fail safely after a calibrations process and are the reference fo...

Страница 5: ...cope of Delivery Sensor DLS2 Mounting bracket BKS W V A 20x20 DLS2 Operation Manual Not in the scope of delivery are Connection cable length according to customer specification Sensor adjustment mount...

Страница 6: ...and material web should be 16 mm 0 62 The 4 screws on the side of the sensor allow tilting the sensor around the focus point This can be required with reflective materials 5 2 Right or left hand posit...

Страница 7: ...to adapt the driver strength of the 24 VDC supply of the controller to the new sensor requirements This is achieved by adding a wire bridge in the 24V supply The table below indicates in which cases t...

Страница 8: ...s not easily recognized In particular if there is little contrast between the background printing and the printed line a disturbance can occur For optimum performance where low contrast is a factor th...

Страница 9: ...ey pad and a LED Display The later is used to display the actual line or edge position or status information of the sensor e g in form of a LED pattern A small green LED is assigned to all keys that o...

Страница 10: ...e of line Pattern recognition not operational Material edge mode Line Reference Position guides on the edge of line Enter profile management list of predefined profiles Select previous next profile fr...

Страница 11: ...calibrate the DLS2 sensor If an existing profile with calibration data was loaded the sensor will change to the Detection Mode The LED line will in this case display the position of the line or edge...

Страница 12: ...the line or edge detection depends form several parameters The focus is an important parameter for proper functioning of the sensor The focus is given by the correct distance between sensor and materi...

Страница 13: ...n of the line The contrast can be measured by pressing once the key The small green LED on the left side of the key will light The contrast quality is visualised by the LED pattern as follows Contrast...

Страница 14: ...operation mode ref to section 8 Press the key that complies with your application Line Detection centre of line Pattern Recognition Line Edge Detection Hologram Detection Material Edge Detection After...

Страница 15: ...h line edges determine and describe each particular line A line will only be recognised as line if following limits are adhered 1 The line width may not differ more then 35 from the reference line 2 T...

Страница 16: ...f none LED is shining the sensor can t recognise the line moving The edge detection mode is indicated by several shining LEDs that gives the position of the material edge in relation to the sensor det...

Страница 17: ...all equipped with FMS components and a DLS2 sensor it may happen that the web guide controller blocks the steering frame This protective function is activated when the line is interrupted and impossi...

Страница 18: ...nel see Fig 7 is used for profile management With it profiles can be stored deleted or implemented After entering the operation mode Profile Management by pressing the key for longer than 0 5 sec the...

Страница 19: ...gement by pressing the key for longer than 0 5 sec 4 Select a free profile storing place with the keys A free profile storing place is marked by a flashing LED It s not possible to overwrite an existi...

Страница 20: ...material sensor can lead to malfunctions An additional electrostatic protection band can be used as illustrated below FMS Force Measuring Systems AG Aspstrasse 6 8154 Oberglatt Switzerland Tel 0041 1...

Отзывы: