5
Installation
5.1
Mounting the Sensor
The sensor requires a square 20x20mm fixation bar that is mounted on the steering
frame according to picture
(Fig. 2)
. The sensor itself is fixed by four M4 screws on the
fixation bracket which is attached to the square bar.
Fig. 2:
Mounting of sensor on the square bar, view of tilting device
DLS200005
The distance between DLS2 and material web should be 16 mm [0.62”].
The 4 screws on the side of the sensor allow tilting the sensor around the focus point.
This can be required with reflective materials.
5.2
Right or left hand position of the sensor
Definition of Left and Right
Left and right are always seen in direction of
the running web (
Fig. 3
).
The DLS2 line sensor can be used on both
sides of the steering frame. The line sensor
can replace an ultrasonic sensor US01/ 04B
or an optical sensor AZS01/04A. No
reconfiguration of the web guide controller
is necessary after the replacement.
Fig. 3:
Left and right
K100007e