Operating Manual CMGZ434
35
Output configuration
Use:
With this parameter, you can choose the output signal depending on
the drive unit used.
Range:
±10V, 0...10V, 0...20mA, 4...20mA
Default:
±10V
Position of line drive
Use:
The output value of the controller depends on the line drive being
mounted before or after the force sensors (ref. to fig. 1). Depending on
the position, the polarity of the output value is different.
Range:
After sensors, Before sensors
Default:
After
sensors
Ramp reference
Use:
To optimize the controller against disturbances, the reference value
should not change too fast. For this, the reference value signal is led
internally to a ramp. Its rate of rise is defined using this parameter.
The length of the ramp defines the settling time the reference will take
to set to the new value.
Range:
0.1
to
20.0
Default:
1.0
Increment:
0.1
Unit:
[s]
Reference Internal / External
Use:
If the reference value will be set using the operating panel or the
interface, this parameter has to be set to
internal
. If the reference value
will be set using a 0...10V signal led to the analog input, this
parameter has to be set to
external
.
Range:
Internal,
External
Default:
Internal
Scale reference input
Use:
This parameter defines how many N resp. kN are assigned to the
0...10 V signal on the analog input.
If no 10V signal is available, you can use a signal with any tension
range, but you must scale the entry in this parameter corresponding to
the tension range. If you have for ex. only a 4V tension (for ex.
terminals d4 / d10 resp. 6 / 9), the needed nominal force value has to
be multiplied with the factor (10V / 4V =
2.5
).
Range:
0
to
9999
Default:
10
Increment:
1
Unit:
[N,kN]